My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0008656 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELDERBERRY
>
13021
>
2600 - Land Use Program
>
PA-0900293
>
SU0008656 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:37 AM
Creation date
9/4/2019 6:00:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0008656
PE
2626
FACILITY_NAME
PA-0900293
STREET_NUMBER
13021
Direction
N
STREET_NAME
ELDERBERRY
STREET_TYPE
CT
City
LODI
APN
05805017
ENTERED_DATE
3/2/2011 12:00:00 AM
SITE_LOCATION
13021 N ELDERBERRY CT
RECEIVED_DATE
3/2/2011 12:00:00 AM
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELDERBERRY\13021\PA-0900293\SU0008656\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
septic system, one percolation test (either a shallow or deep test) must demonstrate a <br /> satisfactory percolation rate within the proposed septic system disposal field. <br /> Only a shallow percolation test was performed. Details and results of the percolation <br /> test are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) --- <br /> P1, ) Satisfactory <br /> 8/25/2011 8/25/2011 3.15 2.4 1 hr. perc. rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "shallow"test is less than or equal to 60 minutes per inch. A satisfactory <br /> percolation rate for a "deep"test is less than or equal to 30 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the sewage disposal area of the Site have demonstrated a satisfactory <br /> percolation rate for the use of a standard septic system in accordance with the <br /> requirements of the San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and pits should follow the San Joaquin <br /> County On-Site Wastewater Disposal Standards (2003) where applicable. <br /> LOGE 1124 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.