My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011665
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELLIOTT
>
20703
>
2600 - Land Use Program
>
PA-1700268
>
SU0011665
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:19 AM
Creation date
9/4/2019 6:04:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011665
PE
2626
FACILITY_NAME
PA-1700268
STREET_NUMBER
20703
Direction
N
STREET_NAME
ELLIOTT
STREET_TYPE
RD
City
LOCKEFORD
Zip
95237-
APN
05121071, 72
ENTERED_DATE
2/12/2018 12:00:00 AM
SITE_LOCATION
20703 N ELLIOTT RD
RECEIVED_DATE
2/9/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\APPL.PDF \MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\CDD OK.PDF \MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\EH PERM.PDF \MIGRATIONS\E\ELLIOTT\20703\PA-1700268\SU0011665\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division: <br /> 1) A building permit for each separate structure or building is required. Submit plans, Specifications, <br /> and supporting calculations, prepared by a Registered Design Professional (architect or <br /> engineer) for each structure or building, showing compliance with the 2016 California Building, <br /> Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes as may be <br /> applicable. Plans for the different buildings or structures may be combined into a single set of <br /> construction documents. <br /> 2) A grading permit will be require for this project. Submit plans and grading calculations, including <br /> a statement of the estimated quantities of excavation and fill, prepared by a Registered Design <br /> Professional. The grading plan shall show the existing grade and finished grade in contour <br /> intervals of sufficient clarity to indicate the nature and extent of the work and show in detail that it <br /> complies with the requirements of the code. The plans shall show the existing grade on adjoining <br /> properties in sufficient detail to identify how grade changes will conform to the requirements of <br /> the code. <br /> 3) The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances. A <br /> complete set of plans must include fire sprinkler plans, truss design submittals, metal building <br /> shop drawings, structural plans and calculations, plumbing, electrical and mechanical drawings <br /> and energy report. <br /> 4) A soils report is required pursuant to CBC§1803 for foundations and CBC appendix§J104 for <br /> grading. All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings. <br /> 5) As noted in the Project Description, the phase two conversion of the existing agricultural <br /> building to a mixed use member's lounge, office and shop will constitute a change of <br /> occupancy. A change of occupancy will require a code analysis report and necessary plans <br /> prepared by an architect or engineer in accordance with the California Existing Building <br /> Code. The report and plans shall identify existing conditions, proposed alterations necessary <br /> to bring the building into compliance with the current code and include the following: <br /> A. Description of proposed use <br /> B. Existing and proposed Occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers(Yes or No) <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> I. Occupant load based on the CBC for the new use <br /> J. Occupant load based on the CPC for the new use <br /> 6) Modifications to existing buildings are required to include upgrades related to disability <br /> access pursuant to the California Existing Building Code. Plans showing these upgrades <br /> must be prepared by a registered engineer or licensed architect and shall be submitted for <br /> review and approval prior to issuance of a building permit. <br /> 7) For each proposed new building, provide the following information on the plans: <br /> A. Description of proposed use <br /> B. Existing and proposed Occupancy Groups <br /> PA-1700268(UP)Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.