Laserfiche WebLink
i <br /> r7C. TURE SEPTIC SYSTEM OPERATIONAL PARAMETERS <br /> . .ell'since the exact operation of the grocery store, deli and kitchen has yet to be completely <br /> determined, a discussion of wastewater disposal operational parameters cannot be quantified at this time. <br /> Consequently, the EHD may require an addendum to this Study that will discuss and detail a new septic <br /> w system for the proposed operation of the entire structures on the property. <br /> IV. CONCLUSIONS AND RECOMMENDATIONS <br /> SSS§ 5.4/The soils underlying a potential leachfield disposal area to serve the Rosetti's Market <br /> and possible Deli/Kitchen show acceptable permeability at the typical leachline depth of 42 <br /> inches, and exceptional permeability at the deeper depths representative of sumps and seepage <br /> pits. <br /> NLS§ 4.2, SSGnilcation <br /> From the soil chemistry test results, it appears that denitrification potential <br /> can be consider medium due to the clay content at the 10 to 15 foot depths where <br /> suppression omay occur. The denitrification potential in combination with <br /> comparatively shallow-rooted landscape plants in the leachfield area should also reduce nitrate <br /> impact by evapotranspiring and mineralizing a percentage of the effluent during favorable weather <br /> times of the year (i.e., April through September). <br /> The well water analytical chemistry results obtained from the on-site domestic well indicate that the <br /> nitrate impact to the underlying aquifers is a surprisingly medium concentration. This is contrary to <br /> what would be expected given the immense amount of agricultural production land area <br /> surrounding the project site. The well water has shown the presence of Total Coliform bacteria for <br /> two separate sampling events. However, after sufficient chlorination, the third sampling event <br /> showed Total Coliform absent. It is recommended that the domestic well be sampled and tested at <br /> least quarterly for Total and Fecal Coliform bacteria. <br /> I <br /> Since the project, in its entirety(Deli and Kitchen operations) are unknown and unquantifiable at <br /> this time, it will be at the request and requirement of EHD of the following: 1.) Additional testing of <br /> the on-site well after chlorination based on two test results for Total Coliform bacteria, 2.) Since <br /> any on-site well will in all likelihood become a public well, EHD may request that a new well be <br /> drilled to meet all requirements, 3.) The installation of a new septic system to serve the commercial <br /> built-out facility separately from the two residential structures, or combine all wastewater from the <br /> entire property into one disposal area, 4.) Reporting design parameters and plans for the proposed <br /> upgrades to the facility. <br /> SS § 6.8. h erage aily Flow is calculated to b 300 gals/da from the public and employee <br /> Res ooms an 300 gpd the two residential structures based o e S.J.C. Sewage Standards. <br /> The Ap icatio at the soil-effluent interface at 4�2 int epth is 0.472 gallons/ft2/day obtained <br /> from the pert rate of 41.7 min/in. <br /> 11 <br /> Chesney Consulting <br />