Laserfiche WebLink
area. 0.67spaces are required for every employee.) (Development Title Section 9-1015.3) <br /> iii. (3) Each parking stall shall be an unobstructed rectangle, minimum nine (9) feet wide and <br /> twenty (20)feet long. (Development Title Section 9-1015.5[b]) <br /> g. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> i. Access driveways shall have a width no less than twenty-five(25)feet for two way aisles and <br /> sixteen (16)feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty (20)feet wide. (Development Title Section 9- <br /> 1015.5[h] <br /> h. LIGHTING: Lighting shall be provided and comply with the following: <br /> i. If the parking area is to-be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> ii. Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that such <br /> light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g] [4]) <br /> i. LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> i. A minimum ten (10)foot wide landscaped strip, respecting the ultimate right-of-way width of <br /> Escalon Bellota Road and State Route 4 Highway shall be installed across the frontage of the <br /> project site. (Development Title Section 9-1020.8) <br /> ii. All areas not used for buildings, parking, driveways, walkways, approved outdoor storage areas, <br /> or other permanent facilities shall be landscaped. (Development Title Section 9-1020.) <br /> j. SCREENING: Screening shall be provided and comply with the following: <br /> i. A solid masonry wall six(6)to seven(7)feet in height shall be erected along the property line of <br /> APN's 187-130-19, 13,20 and 05. (Development Title Section 1022.4[d][1]) <br /> ii. All storage materials and related activities, including storage areas for trash, shall be screened <br /> so as not to be visible from adjacent properties and public rights-of-way. Screening shall be six <br /> (6)to seven (7)feet in height. Outside storage is not permitted in front yards, street side yards, or <br /> in front of main buildings. (Development Title Section 1022.4[d][21) <br /> k. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five(5)feet from <br /> any future right-of-way line, including any corner cut-off(snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> I. BUILDING CODE REQUIREMENTS: The following Uniform Building Code and San Joaquin <br /> County Ordinance requirements will be applicable and shall be incorporated in the construction plans <br /> before submittal to the Building Inspection Division: <br /> i. A grading plan shall be submitted and approved and a grading permit issued by the Building <br /> Inspection Division prior to performing any excavation or filling of earth material: <br /> ii. The Construction Site Plan shall indicate the following: <br /> iii. Provide parking for the physically disabled. The space(s) shall be located as close as possible <br />