Laserfiche WebLink
3.7 Description of Proposed or Expected Maximum (including second unit dwellings) se tic <br /> tank usage on site. There are two existing homesites and a fruitstand. As stated prior, the site <br /> � will include a 3,000 square foot gas station, an 18,000 square foot hotel, and a 53,000 square feet <br /> F of commercial/retail area, if the rezone classification is approved. Septic systems will need to be <br /> designed for each use. <br /> 4.0 GROUNDWATER INFORMATION SECTION: <br /> { <br /> 4.1 Description of the depth and gradient of groundwater in the general area: The depth to <br /> ground water in this area is approximately 110 feet according to the map of"Lines of Equal <br /> Depth to Groundwater" published Spring, 1999, by the San Joaquin County Flood Control and <br /> Water Conservation District. The gradient descends from east to west. <br /> ✓4.2 Description/Discussion of any existing and/or potential groundwater contamination <br /> issues in the general location of the site: The concerns for groundwater contamination in this <br /> area are deemed moderate due to the depths involved. Insecticides, pesticides, and fertilizers <br /> typically do not significantly impact groundwater at these depths. However, as with any <br /> agricultural area, there is always potential for contamination due to chemicals used in the <br /> farming operation. <br /> V4.3 Description of location, type and construction of well and location where water <br /> sample(s)were obtainon�ovemberter samp ever takenfrom a spigot at the domestic well located <br /> at 17336 Highway 81, 2008 b Mike Toy of Dillon&Murphy <br /> ✓4.4 Description of constituents being tested for in the water sample: The water samples were <br /> tested for nitrates and DBCP. <br /> -/45 Description of how sample was obtained, handled, stored, and transported to the lab: <br /> The water samples were obtained from the spigot at the well located at 17336 Highway 88. The <br /> samples were taken by Mike Toy of Dillon & Murphy, and driven to directly to Precision <br /> Enviro-Tech. The samples were taken and handled in accordance with Precision Enviro-Tech <br /> requirements. The results from the test can be found in the Appendix. <br /> ✓4.6 Complete Chain of Custody document, including printed and signed name of third <br /> party sampler, condition of sample and date and time the sample was submitted to the lab. <br /> For Laboratory samplers, complete laboratory report to include the above noted <br /> information: <br /> The complete chain of custody document is located in the Appendix. <br /> 5.0 SOIL PROFILE INFORMATION SECTION: <br /> ✓5.1 Site map showing location,with dimensions, of the soil profile pit on the parcel: See <br /> Appendix. <br /> /5.2 Description of soil profile pit including depth and dimensions: The shallow test hole was <br /> prepared per County Standards. The hole was excavated to a depth of 42 inches and 8 inches in <br /> diameter. It was backfilled with 2 inches of"pea gravel". <br /> Fr` <br /> 2 <br /> F,� <br /> c:1085715oil Suitability Report 120308 <br />