SU0011507 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRAZIER
>
17508
>
2600 - Land Use Program
>
PA-1700190
>
SU0011507 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:13 AM
Creation date
9/4/2019 6:38:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0011507
PE
2622
FACILITY_NAME
PA-1700190
STREET_NUMBER
17508
Direction
E
STREET_NAME
FRAZIER
STREET_TYPE
RD
City
LINDEN
Zip
95236-
APN
06510008
ENTERED_DATE
9/26/2017 12:00:00 AM
SITE_LOCATION
17508 E FRAZIER RD
RECEIVED_DATE
9/25/2017 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRAZIER\17508\PA-1700190\SU0011507\SS STUDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S = Sufficient <br /> I = Insufficient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> ❑ 6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> ❑ 6.2 The minimum number of shallow and deep percolation tests was performed for each parcel. <br /> FA El 6.3 Description of the date,time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> ❑ 6.4 Description of the date, time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br /> depth to water remaining in hole, etc.) <br /> ❑ 6.5 The test conformed to SJC Policy EHD 02-02(correct depth,diameter,2"gravel, 6"water refill, correct readings <br /> recorded). <br /> U�t ❑ 6.6 Complete Percolation Test Form (including readings)was provided with REHS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> ❑ 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. <br /> ❑ 6.8 Discussion of percolation rates in relation to the type,size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: Jeffrey Wong � <br /> Reviewed Date: <br /> U / <br /> 1 <br /> FT-M 26-02-003 Pace 2 of Snil.Snitahility Checklist <br />