Laserfiche WebLink
2092494E-4.2 ESS-11D ENGIi� F li��� �Ha� <br /> the map, gives constructive notice to title companies,future property buyers and the <br /> public of ti-le requirement to provide a private irrig-ataon easement as well as its size <br /> and location_ <br /> b. Obtain a stntctttre permit far new service structure connections to District facilities <br /> Zvlliel� are necessary to provide service to the near parcels. <br /> C- The design strength and diameter of the proposed private pipelines and structures <br /> shall be adequate to Dandle st-u7dard delivery heads or flows for that area. <br /> If a recorded map is not required, the above stated conditions shall be recorded in <br /> conjunction with the recording of deeds for the newly created parcels. <br /> 3. The owner shall gi ant ease malts of sufficient width for all District facilities which tray <br /> exist on subject property to serve as a replaceraent for any prescriptive arzd/or unrecorded <br /> casements t1lat are present. All. existing recorded or newly dedicated District easernertts <br /> shall ba shotivn and identified on the survey map prior to its recording_ if a map is riot <br /> required, easements shall be recorded by separate inst.nmient concurrent with the <br /> recordation of new deeds. <br /> 4. Owner shall obtain an Encroachment Permit front District for fencing or any other <br /> proposed encroachments of District eFasemc!nts resulting from the proposed parcel split. <br /> Owner shall provide District u-ath unrestricted access to its pipeline and control structures. <br /> S. if a proposed homesite or building area is louver than adjacent irrigated property-, a <br /> permarien,t berm or ditch will need to be constructed around the homesite parcel or <br /> building site,to prevent accidental flooding from irrigation water. Property owner skull <br /> either verify field elevations or submit a w itl.en statement to District indicating that <br /> property in question is not subject to flooding from adjacent irrigated property or <br /> pipelines. Likewise, owner sliall provide the District with a written statement or <br /> cxplanation if any of the above stated conditions do not pertain to the situation involving <br /> the proposed minor subdivision. <br /> 6. A copy of the survey niap. if required, shall be provided to the District Engineering <br /> Department for review to ensure that the above conditions have been satisfied. <br /> if you have any questions,please contact me in the Engineering Department at(209)249-4617. <br /> Very truly yours, <br /> Sam Balogna <br /> Engizt.eering Department Manager <br /> 2 <br />