My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0009045
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREWERT
>
920
>
2600 - Land Use Program
>
PA-1200011
>
SU0009045
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:50 AM
Creation date
9/4/2019 6:44:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0009045
PE
2626
FACILITY_NAME
PA-1200011
STREET_NUMBER
920
Direction
W
STREET_NAME
FREWERT
STREET_TYPE
RD
City
LATHROP
APN
19126022
ENTERED_DATE
1/30/2012 12:00:00 AM
SITE_LOCATION
920 W FREWERT RD
RECEIVED_DATE
1/27/2012 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FREWERT\920\PA-1200011\SU0009045\APPL.PDF \MIGRATIONS\F\FREWERT\920\PA-1200011\SU0009045\CDD OK.PDF \MIGRATIONS\F\FREWERT\920\PA-1200011\SU0009045\EH COND.PDF \MIGRATIONS\F\FREWERT\920\PA-1200011\SU0009045\CORRESPOND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
entrance (C.C.R., Title 24). (2.0 spaces are required for every 1,000 feet of building area) <br /> (Development Title Section 9-1015.3). <br /> e) ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> (1) Access driveways shall have a width of no less than twenty-five (25)feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty (20) feet wide. (Development Title Section 9- <br /> 1015.5[h][1]) <br /> f) LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> (1) A minimum ten (10) foot wide landscaped strip, respecting the ultimate right-of-way width of <br /> Frewert Road, shall be installed across the frontage of the project site (Development Title <br /> Section 9-1020.7).The existing landscaping satisfies this requirement. <br /> (2) Areas of the property which are not part of the project shall be barricaded from traffic and kept <br /> mowed and dust free. <br /> g) NOISE: The project shall meet the requirements of Development Title Section 9-1025.9 Noise. <br /> Stationary noise sources shall not exceed an Hourly Equivalent Daytime Sound Level of 50 dB or a <br /> Maximum Daytime Sound Level of 70 dB. The project will not operate at night. <br /> (1) A 14-foot tall noise barrier shall be constructed to the east and south side of the chip and grind <br /> area. <br /> (2) The barrier shall be of solid and durable material without any air gaps and shall break line of site <br /> from the chip and grind area to the nearest residential receptors to the east. Appropriate noise <br /> barrier material shall include concrete panels, concrete block, pre-fabricated acoustical barriers, <br /> or earthen berms. Other materials may be used if reviewed by a qualified noise control engineer <br /> and approved by the Community Development Department. <br /> (3) The grinder shall operate only between the hours of 7:00 a.m. and 4:00 p.m. <br /> h) REVIEW:A yearly review shall be conducted by the Community Development Department. <br /> i) SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be <br /> included on the Site Plan. All portions of any sign shall be set back a minimum of five (5) feet from <br /> any future right-of-way line, including any corner cut-off (snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> j) BUILDING CODE REQUIREMENTS: The following California Building Code and San Joaquin <br /> County Ordinance requirements will be applicable and shall be incorporated in the construction plans <br /> before submittal to the Building Inspection Division: <br /> (1) Provide restrooms conforming with all disabled access requirements (C.C.R., Title 24). (The <br /> existing restrooms meet this requirement) <br /> 2) DEPARTMENT OF PUBLIC WORKS: (Staff Contact:: Alex Chetley, [209]468-3000) <br /> a) The developer shall provide drainage facilities and meet the requirements of San Joaquin County <br /> Development Standards to prevent the increased runoff release rate of storm water from discharging <br /> San Joaquin County PA-1200011Nalley Organics <br /> Community Development Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.