Laserfiche WebLink
Y :f <br /> A <br /> SIrE PLAN CHECK LIST <br /> • r,.Size: .r. .f. N.r . ..,, L4N_CHECKU5Tr <br /> The site plan must be drawn on 18"x 26"reproducible material. <br /> North Arrow,Date and Scale: Use an engineer's scale ge., 1"to 20'or 1'to 401,preferred). The direction of <br /> "north"should be pointing towards the top of the page. <br /> Streets and Easements: Location and names of all streets and easements bordering on the property with access <br /> details. <br /> • Property Lines: All existing and proposed property lines or boundary lines of the parcel with dimensions. <br /> each Parcel 1,2,3,4,etc.and indicate the net square!footage(acreage)of each. Labe! j <br /> Vicinity Map: A vicinity map showing the location of thero <br /> P perty in relation to surrounding streets. I <br /> ' Names and Signatures: Name,signature,address and telephone number of owner,•the name,address and <br /> telephone number of the owner,surveyor or engineer fling the map. <br /> • Contour Lines: Contour lines or spot elevation relative to mean sea level datum. <br /> • Dedications: Improvements and easements to be dedicated to the County. { <br /> E• i <br /> '.I <br /> Existing and Proposed Development. All existing structures flabeledevistingg and an y <br /> (labeled'proposed with dimensions,square footage and distances from other structures and ex sting atnd <br /> Proposed property lines. Any existing structures planned for removal should be shown with dashed lines. The it <br /> use and number of floors should be labeled on each structure. <br /> Parking and Driveways: The location,dimensions and surface material of all existing and proposed parking and <br /> driveways. <br /> 9 <br /> Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150'of the <br /> Proposed development. Wells must be meet the following setbacks: <br /> 5'from structures; <br /> 50'from septic tanks; 1 <br /> E <br /> 100'from leach lines; <br /> 150'from sumps or seepage pits;and <br /> 10'from property lines. <br /> I <br /> If public water will be utilized,a "will-serve"letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location ofthe sewer outlet,public sewer hook-up,or existing and proposed <br /> sewage disposal systems including leach field areas and any off-site sewage disposal systems within 150'of the <br /> Prop8rty. h <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property lines,siructures,m driveways and swimming pools; <br /> 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> 10'from structures, driveways and swimming pools; ! <br /> 100'from wells,streams and waterways. <br /> - 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining <br /> properties(this requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized,a "will-serve'letter must be submitted from the service provider. <br /> I <br /> • Storm Drainage: The location of existing and proposed storm drainage facilities(check with Engineering staff <br /> regarding design criteria). If subject to flooding, the 100-year flood eievations must be shown. Indicate any <br /> unusual topographic features of the site(e.g.steep slopes, or drainage courses). <br /> Watercourses: The location of existing watercourses and the extent of any levee, with toe and crown indicated. <br /> • Flooding. The area subject to flood from an intermediate regional flood and depth of food waters,if applicable. l <br /> Proposed method of food protection if property is subject to inundation from an intermediate regional food or <br /> other food hazard. <br /> mimiiwy <br /> SITE PLANS MUST BE COMPLETE AND LEGIBLE <br /> t <br /> fBefore.applying,-checkkyour site plan:to-make•sureYhat ucontains all of the6ffn anon cited aove. You are <br /> encouraged to have one of our counter staff review the draft Site Plan prior to having copies run. <br /> • Faint prints and light blue lines cannot be accepted because they cannot be reproduced or microfilmed. <br /> a <br /> :I <br /> i <br /> PA LA99 AYgu51 24,19" ' <br /> _7_ <br /> �I <br /> E <br /> t <br />