Laserfiche WebLink
KLEINFELDER <br /> An employee owned company <br /> File No. 32585.G01 <br /> September 22, 2003 �C�I �MIM <br /> Ms. Stacey Griffeth SEP 2 3 2003 <br /> 11875 East Mayers Road EM/1RONMENT, <br /> Acampo, CA 95220PHM EiV CESTH <br /> Subject: DISCUSSION OF PERCOLATION TEST P-17 <br /> 18882 E. GAWNE ROAD <br /> STOCKTON, CALIFORNIA <br /> Dear Ms. Griffeth: <br /> As requested by Mr. Mike Huggins of San Joaquin County Environmental Health Department (SJCEHD), <br /> we present this letter discussing Test Hole #1 at Percolation Test P-17 performed on July 8, 2003 as part of <br /> the soil suitability study dated August 13, 2003. Mr. Eduardo Rodriguez performed the percolation test, and <br /> Mr.Michael Escatto was the SJCEHD inspector. <br /> The following is based on a discussion with Mr. Rodriguez as well as a review of the percolation test data <br /> sheets from July 8, 2003. The two percolation tests inspected prior to P-17 were P-8 and P-1. The final <br /> readings for Test Hole #1 of the previous two tests showed that all the water had percolated out of the test <br /> holes. As Percolation Test P-8 was inspected, Mr. Escatto wrote "Empty" next to the final reading for Test <br /> Hole #1 and instructed Mr. Rodriguez to specifically state when a given hole is empty. Upon completion of <br /> Percolation Test P-1, Mr. Rodriguez wrote "Empty" next to the last reading of Test Hole #1 as instructed. <br /> As previously stated, the percolation test inspected following P-8 and P-1 was P-17. Based on the water <br /> level readings at 3:40 and 4:10,the test hole was clearly not empty. In addition,the test hole was not refilled <br /> after the reading at 3:40. However, as test P-17 was inspected, it appears that a misunderstanding occurred <br /> regarding the previously inspected Percolation Tests P-8 and P-1. Believing that Mr. Rodriguez had stated <br /> that the test hole was empty on the last two readings (Mr. Rodriguez referring to tests P-8 and P-1), Mr. <br /> Escotto incorrectly wrote "Empty" next to the final two readings of Percolation Test P-17 and recorded <br /> below his signature that the two readings were empty. We note that English is Mr. Rodriguez's second <br /> language. <br /> In conclusion, due to a misunderstanding between Mr. Rodriguez and Mr. Escatto, Test Hole #1 of <br /> Percolation Test P-17 was incorrectly recorded as being empty. However, it is our opinion that the numerical <br /> readings for the test as well as the recorded percolation rate of 14.7 minutes per inch are correct. <br /> We trust that this letter meets your needs at this time. If you have any questions,please contact our office. <br /> Respectfully submitted, <br /> KLEINFELDER <br /> R J. Olsen, C.E. <br /> Staff Engineer <br /> RJO:lr cc: Mr.Mike Huggins—SJCEHD <br /> ST03L530 ©2003 Kleinfelder,Inc. <br /> KLEINFELDER 2825 East Mvrtle Street,Stockton, CA 95205-4794 (209)948-1345 (209)948-0621 fax <br />