My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0008455
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
16215
>
2600 - Land Use Program
>
PA-1000217
>
SU0008455
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:31 AM
Creation date
9/5/2019 10:43:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0008455
PE
2626
FACILITY_NAME
PA-1000217
STREET_NUMBER
16215
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
20919033
ENTERED_DATE
9/23/2010 12:00:00 AM
SITE_LOCATION
16215 W GRANT LINE RD
RECEIVED_DATE
9/23/2010 12:00:00 AM
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\16215\PA-1000217\SU0008455\REV EH COND.PDF \MIGRATIONS\G\GRANT LINE\16215\PA-1000217\SU0008455\APPL.PDF \MIGRATIONS\G\GRANT LINE\16215\PA-1000217\SU0008455\CDD OK.PDF \MIGRATIONS\G\GRANT LINE\16215\PA-1000217\SU0008455\EH COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> 7 <br /> - S>I fE PLAN CHECK LIST <br /> SITE PLAN CHECK LIST <br /> • Size: The Site Plan must be drawn on minimum 18"x 24" reproducible material. <br /> • North Arrow, Date and Scale: Use an engineer's scale (i.e., 1"to 20'or 1"to 40', preferred). The direction of <br /> "north"should be pointing towards the top of the page. <br /> • Streets and Easements: Location and names of all streets and easements bordering on the property with <br /> access details. <br /> • Property Lines: All property lines or boundary lines of the parcel with dimensions. <br /> • Vicinity Map: A vicinity map showing the location of the property in relation to surrounding streets. <br /> • Existing and Proposed Development: All existing structures (labeled"existing')and any proposed structures <br /> (labeled 'proposed')with dimensions, square footage and distances from other structures and property lines. <br /> Any existing structures planned for removal should be shown with dashed lines. The use and number of floors <br /> should be labeled on each structure. <br /> • Parking and Driveways: The location, dimensions and surface material of all existing and proposed parking and <br /> driveways. Calculations indicating the number ofrequired spaces must be shown. (Refer to'County Parking <br /> Lot Standards'). <br /> • Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150' of the <br /> proposed development. Wells must be meet the following setbacks: <br /> - 5'from structures; <br /> - 50'from septic tanks; <br /> - 100'from leach lines; <br /> - 150'from sumps or seepage pits; and <br /> - 10'from property lines. z <br /> If public water will be utilized, a."wilkserve" letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location of the sewer outlet, public sewer hook-up, or existing and proposed <br /> sewage disposal systems and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property lines, structures, driveways and swimming pools; <br /> - 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> - 10'from structures, driveways and swimming pools; <br /> - 100'from wells, streams and waterways. <br /> - 5'to 75'from property lines depending on zoning or the location of septic systems on adjoining properties <br /> (this requirement also applies to seepage pits). <br /> If public sewage disposal will be utilized, a"will-serve" letter must be submitted from the service provider. <br /> • Storm Drainage: The location of existing and proposed storm drainage facilities (check with Engineering staff <br /> regarding design criteria). If subject to flooding, the 100-year flood elevations must be shown. Indicate any <br /> unusual topographic features of the site (e.g. steep slopes, or drainage courses). Grading and contours need to <br /> be shown. <br /> • Landscaping: The location of existing and proposed landscaping and trees 6"or greater in diameter (note any <br /> trees to be removed). Calculation indicating the percentage of the net site area to be landscaped must be <br /> shown. (Refer to County Landscaping Standards). <br /> • Signs, Fences, Storage and Trash Enclosures: The location of and height of all existing and proposed signs <br /> and fences and the location and dimensions of all open and/or enclosed storage and trash receptacles. <br /> SITE PLANS MUST BE COMPLETE AND LEGIBLE <br /> • Before applying, check your Site Plan to make-sure that it contains all of the information cited above. You are <br /> i <br /> encouraged to have one of our counter staff review your draft Site Plan prior to having copies run. <br /> • Faint prints and light blue lines will not be accepted because they cannot be reproduced or microfilmed. <br /> I <br /> F:IDEVSVMPlanning Application Forms\Use Permit.(Revised 02-03-10) Page 8 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.