My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006253 (2)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
20058
>
2600 - Land Use Program
>
PA-0600363
>
SU0006253 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2019 11:40:20 AM
Creation date
9/5/2019 10:46:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006253
PE
2611
FACILITY_NAME
PA-0600363
STREET_NUMBER
20058
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
MOUNTAIN HOUSE
APN
20907026
ENTERED_DATE
9/15/2006 12:00:00 AM
SITE_LOCATION
20058 W GRANT LINE RD
RECEIVED_DATE
9/12/2006 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\20058\PA-0600363\SU0006253\REV SITE PLN.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1078
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
pollution prevention/good housekeeping for municipal operations. The applicant would <br /> submit the SWMP to the County when submitting project improvement plans. The County <br /> and the MHCSD would review these plans prior to Final Map approval. <br /> o Water Supply. Water supply will be provided by the MHCSD from the water treatment <br /> plant located on the north side of Byron Road. Pipelines would be extended along Central <br /> Parkway from Neighborhoods C and D. <br /> [Note: MHCSD is processing an agreement with the San Joaquin Delta Community <br /> College District for a site for two 3.7 million gallon treated water storage tanks at the <br /> northeast corner of the Delta College campus property to facilitate development in <br /> Specific Plan III. (The Delta College campus property is located immediately south of the <br /> Altamont Heights Project.) One reservoir to serve Pressure Zone 2 must be constructed <br /> before development of the Altamont Heights Project can occur. In addition, two booster <br /> pump stations must be constructed to provide sufficient flow and pressure to meet peak <br /> hour and fire fighting demands. The first is required to serve the project site. The second <br /> pump station will be constructed as later phases of the Mountain House Community are <br /> developed. The piping system at the storage tank and pump station site will be designed <br /> so the pump stations can draw water from either tank, thereby providing flexibility to <br /> system operation.The applicant for the Altamont Heights Project will be required to pay <br /> its fair share of the costs of the Zone 2 tank, pressurization pump station, and distribution <br /> pipelines to the project site.] <br /> o Wastewater. MHCSD will provide wastewater service. The MHCSD operates a <br /> wastewater treatment plant located north of Byron Road. Wastewater from the project <br /> site would be conveyed through an on-site sanitary sewer collection system. This system <br /> would include an 8-inch main line, service laterals, maintenance holes, and cleanouts, <br /> which would serve the entire development. The sewer lines would be installed along the <br /> streets prior to paving. <br /> o Agricultural Fence, Landscape Buffers/Easements and Retaining Walls. As required by <br /> Specific Plan III (Implementation Measures 3.2.3.3 (e)and 4.2.8.3 (f)), an agricultural fence <br /> would be constructed along the north and west sides of the project(but still within the <br /> project)adjacent to Grant Line Village. The agricultural fence would be a vinyl 3-rail fence, <br /> 4%z feet in height,consistent with the design specifications of the MHCSD Design Manual <br /> (Chapter 4)and Specific Plan III (Figure 4-27). Along the north side of the project(i.e., at <br /> the rear of lots 1,2, 11, 12,and 13),the agricultural fence would be located 8 feet from a <br /> retaining wall up to 7 feet in height. Along the west side of the project, the agricultural fence <br /> would be constructed along the eastern edge of the 30-foot wide right-of-way access <br /> easement. Along the northwest side of the project(immediately adjacent to Assessor parcel <br /> 209-070-27), the agricultural fence would be constructed at the property line. (See Figure 6) <br /> As specified by Specific Plan III (Implementation Measure 3.2.3.3 (e)), a continuous 8-foot <br /> wide landscape buffer/easement(within the project boundary)would abut the agricultural <br /> fence. On the east side of the property, a second 8-foot wide landscape buffer(within the <br /> project boundary)would parallel"F Street. This landscape buffer would feature large <br /> canopy trees, set 5 feet behind the sidewalk and matching the street trees along"F"Street, <br /> consistent with Specific Plan III (Figure 4-10)and the MHCSD Design Manual (Chapter 3). <br /> (See Figures 6 and 7). <br /> The retaining wall,landscape buffers, and agricultural fence would require the establishment <br /> of a maintenance entity or financing mechanism acceptable to the MHCSD to provide <br /> funding for maintenance(and, if necessary, replacement)of the improvements. Access to <br /> said improvements would be provided by means of access easements as specified by the <br /> MHCSD. (See Figure 6) <br /> 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.