My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006254
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
20058
>
2600 - Land Use Program
>
PA-0600364
>
SU0006254
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2020 3:43:59 PM
Creation date
9/5/2019 10:46:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006254
PE
2691
FACILITY_NAME
PA-0600364
STREET_NUMBER
20058
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
MOUNTAIN HOUSE
APN
20907026
ENTERED_DATE
9/15/2006 12:00:00 AM
SITE_LOCATION
20058 W GRANT LINE RD
RECEIVED_DATE
9/12/2006 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\20058\PA-0600364\SU0006254\CDD OK.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1070
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MOUNTAIN HOUSE PROPOSED ALTAMONT HEIGHTS TENTATIVE MAP 4. ENVIRONMENTAL CHECKLIST <br /> 4.11 NOISE <br /> _ SPIIIEIR Mitigation Measure 4.13-2 requires that commercial/office and limited industrial <br /> buildings on the east side of the Machado property and in the Mountain House Business Park, <br /> be designed to ensure that noise from outdoor equipment does not exceed 55 dBA Leq during <br /> daytime hours(7:00 a.m. to 10:00 p.m.), or 50 dBA Lq during nighttime hours (10:00 p.m. to <br /> 7:00 a.m.)at off-site noise-sensitive receptors (i.e.,residences and schools).Noise studies <br /> shall be conducted to ensure that acceptable noise levels are not exceeded. <br /> With regard to landscape maintenance, SPIIIEIR Mitigation Measure 4.13-2 requires that <br /> equipment be equipped with properly operating exhaust mufflers and engine shrouds and, for <br /> maintenance within 320 feet of noise-sensitive land uses (e.g., residences), operation of <br /> equipment shall be limited to the hours from 7:00 a.m. to 10:00 p.m. <br /> Implementation of the above mitigation measure would reduce new stationary source noise <br /> impacts to a less-than-significant level. <br /> A soundwall is planned for the south side of Grant Line Road(EDAW, 2005a, Figure 11-1). <br /> In addition, SPIIIEIR Mitigation Measure 4.13-4 requires sound barriers(walls or berms) <br /> along seven segments of arterial streets (identified in Table 4.13-11 of the SPIIIEIR)to <br /> attenuate traffic noise. One segment is along Central Parkway south of Grant Line Road and <br /> another is along Central Parkway at the community park and Delta Community College. <br /> Mitigation Measure 4.13-4 also requires that sound barriers be constructed along the north <br /> side of Interstate 205 when acoustical monitoring indicates noise levels from freeway traffic <br /> are greater than the applicable noise thresholds at residential neighborhoods,the community <br /> park,the community college, and at limited industrial sites. <br /> Mitigation Measure 4.13-4 also requires individual projects that do not comply with interior <br /> noise standards included in the San Joaquin County Development Title guidelines to use <br /> mitigation measures, such as dual-pane windows and exterior wall insulation,to reduce <br /> interior noise exposure to 45 dBA Ld„/CNEL. These features are common for current <br /> residential construction in California. <br /> �. Where individual projects do not comply with exterior noise standards of the San Joaquin <br /> Development Title, Mitigation Measure 4.13-4 requires that mitigation measures, such as <br /> noise barriers and setbacks between noise sources and sensitive receptors,be implemented to <br /> reduce exterior noise levels. <br /> Implementation of MM 4.13-4 would reduce noise impacts on residents in the proposed <br /> L project to a less-than-significant levels. <br /> DISCUSSION REGARDING PROPOSED PROJECT <br /> a) Exposure of persons to or generation of noise levels in excess of standards established <br /> in the local general plan or noise ordinance, or applicable standards of other <br /> agencies? <br /> 4-56 <br />
The URL can be used to link to this page
Your browser does not support the video tag.