My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003056
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10998
>
2600 - Land Use Program
>
SA-94-31
>
SU0003056
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:29:39 AM
Creation date
9/5/2019 10:57:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0003056
PE
2633
FACILITY_NAME
SA-94-31
STREET_NUMBER
10998
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
ENTERED_DATE
11/6/2001 12:00:00 AM
SITE_LOCATION
10998 S HARLAN RD
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\10998\SA-94-31\SU0003056\APPL.PDF \MIGRATIONS\H\HARLAN\10998\SA-94-31\SU0003056\CDD OK.PDF \MIGRATIONS\H\HARLAN\10998\SA-94-31\SU0003056\EH COND.PDF \MIGRATIONS\H\HARLAN\10998\SA-94-31\SU0003056\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Referral, Page Two <br /> g. All recommendations of the soils engineer that were <br /> included in the soils report shall be incorporated in the <br /> construction drawings. <br /> h. Provide a copy of the Soils Report to the Building <br /> Inspection Division. <br /> i. The proposed project is located within an expansive soil <br /> area where a conventional foundation may not be suitable. <br /> Therefore, an engineer is required to evaluate the <br /> foundation design. <br /> j . The proposed project is located in a subsidence area <br /> where a conventional foundation may not be suitable. <br /> Therefore, a complete soils report by a geotechnical <br /> engineer is required. <br /> k. Provide a technical opinion and report to identify and <br /> develop methods of protection from the hazards presented <br /> by the hazardous material. (U.B. C. Section 901 (F) <br /> A grading plan shall be submitted and approved and a grading <br /> permit issued by the Building Inspection Division prior to <br /> performing any excavation or filling of earth material: <br /> U A grading plan shall contain the information listed in <br /> the U.B. C. , Appendix, Chapter 70, Section 7006 (1) . <br /> The grading plan shall include complete drainage details <br /> and elevations of the adjacent parcels. Retaining wall <br /> details shall be submitted where applicable. <br /> n Grading in excess of 5, 000 cubic yards shall comply with <br /> Section 7014 for "Engineered Grading Requirements . " <br /> d. Al'_ recommendations of the soils engineer shall be <br /> _nccrporatad in the grading plans . <br /> e. All compaction reports must be submitted prior to a <br /> -foundation inspection. <br /> All grading permits are subject to approval by the other <br /> departments . <br /> �g All grading authorized by the nermit shall be approved <br /> U prier to issuance of any building permits, or beginning <br /> of anv construction. <br /> Note: This anollcatlon recruires a discretionary approval, <br /> (e . g. '.e.^.tative dap, Site Approval, Use Permit) . Therefore, <br /> a radincpermit will not be issued until this approval is <br /> obtained. <br />
The URL can be used to link to this page
Your browser does not support the video tag.