ti <br /> e. LIGHTING: YLighting shall be provided and comply with the following: <br /> (1) If the parking area is to be used at night, parking lot and security lighting shall be installed. <br /> (Development Title Section 9-1015.5[g]) <br /> (2) Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines hall be permitted except onto public thoroughfares,provided, however, that such <br /> light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g]]4]) <br /> f. LANDSCAPFNG: Landscaping shall be provided and comply with the following: <br /> (1) A minimum ten (10) foot wide landscaped strip, respecting the ultimate right-of-way width of <br /> Harlan Road, shall be installed across the frontage of the project site where development occurs. <br /> (Development Title Section 9-1020.8) <br /> A. Note: The ten foot wide landscaped strip will be required along the southern 130 feet of the <br /> western property line. <br /> (2) All areas:not used for buildings, parking, driveways, walkways, approved outdoor storage areas, <br /> or other.,permanent facilities shall be landscaped:(Development Title Section 9-1020.8) <br /> g. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> (1) Access driveways shall have a width of no less than twenty-five (25) feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty(20)feet wide. (Development Title Section 9-1015.5) <br /> h. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title with the <br /> following modifications and be included on the Site Plan. All portions of any sign.shall be set back a <br /> minimum of,five (5) feet from any future right-of-way line, including any corner cut-off (snipe)_ <br /> (Development Title Section 9-1710.2[g]) <br /> i. BUILDING CODE-REQUIREMENTS: The following Uniform Building Code and San Joaquin <br /> County Ordinance requirements will be applicable and shall be incorporated in the construction plans <br /> before submittal to the Building Inspection Division: <br /> 4 <br /> (1) The proposed use will change the occupancy from a S occupancy to a F occupancy (UBC <br /> Section:3405). The structure must be brought into compliance with current code provisions <br /> includingstructural, plumbing, mechanical, electrical, energy and disabled access requirements. <br /> A licensed architect or registered engineer shall prepare all documents. <br /> (2) The existing structure exceeds the allowable floor area permitted by the California Building Code <br /> for a F-1 occupancy or type IIB construction. The building shall be provided with an automatic <br /> fire sprinkler system, change type of construction, or separated into conforming areas with area <br /> separation walls. <br /> (3) Exterior;walls less than 5 feet from the property line shall be of one hour fire-resistive <br /> construction. Openings will not be permitted less than 10 feet and protected less than 5 feet. <br /> (4) Provide parking for the physically disabled. The space(s) shall be located as close as possible <br /> to the primary entrance. (C.C.R., Title 24). <br /> Conditions of Approval -2 - PA-0800359 <br /> T, <br />