My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0007830 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
10726
>
2600 - Land Use Program
>
PA-0900165
>
SU0007830 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:15 AM
Creation date
9/5/2019 10:58:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0007830
PE
2622
FACILITY_NAME
PA-0900165
STREET_NUMBER
10726
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
APN
06318001
ENTERED_DATE
7/17/2009 12:00:00 AM
SITE_LOCATION
10726 E HARNEY LN
RECEIVED_DATE
7/17/2009 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARNEY\10726\PA-0900165\SU0007830\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Hieb Family 1990 Trust Prouty Page 9 of 11 <br /> Our Project Number: E0719..J <br /> December 17, 2007 <br /> Table 4. <br /> Sum ary of Percolation Tests <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> i Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P-1 (Deep) 24.10 62.5 4-hr Failing perc rate <br /> i r�'• 12-14-07 <br /> P-2 (Shallow) 3.25 125 4-hr Failing perc rate <br /> 12-14-07 <br /> FJ Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch. <br /> A satisfactory percolation rate for a"deep"test is less than or equal to 30 minutes per inch. <br /> El <br /> 6.7 Discussion of Percolation Test Results <br /> The soils within the sewage disposal areas of the site have not demonstrated a satisfactory <br /> percolation rate in accordance with the requirements of the EHD for the use of a standard <br /> 0 septic system. <br /> 6.8 Discussion of Septic System Sizing <br /> Pt The proposed Parcels 1 is suitable for an engineered septic system. We recommend a Civil <br /> Engineer prepare a septic system design for Parcels 1 unless additional percolation testing on <br /> the Parcel indicates a satisfactory rate is achieved and approved by the EHD. <br /> - Septic System Construction should follow the San Joaquin County On-Site Wastewater Disposal <br /> Standards where applicable. <br /> 7.0 CONCLUSIONS <br /> fiIn summary, the parcel appears suitable for an engineered septic system. We recommend a <br /> Civil Engineer prepare a septic system design for Parcels 1 unless additional percolation testing <br /> on the Parcel indicates a satisfactory rate is achieved and approved by the EHD. <br /> _3 No ground water was encountered in any of the borings drilled on the property to a maximum <br /> of 25 feet. The on-site water well was tested for nitrate and DBCP. These results are still <br /> Fjpending and will be submitted to the county in a separate letter. <br /> F1 <br /> i <br /> k <br /> 902 Industrial Way•Lodi,CA 95240•209.367.3701 •Fax 209.369.4228 02007 Neil 0.Anderson&Associates, Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.