My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0003940
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
14238
>
2600 - Land Use Program
>
PA-0200551
>
SU0003940
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:30:22 AM
Creation date
9/5/2019 10:59:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0003940
PE
2622
FACILITY_NAME
PA-0200551
STREET_NUMBER
14238
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
ENTERED_DATE
5/11/2004 12:00:00 AM
SITE_LOCATION
14238 E HARNEY LN
RECEIVED_DATE
11/26/2002 12:00:00 AM
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARNEY\14238\PA-0200551\SU0003940\APPL.PDF \MIGRATIONS\H\HARNEY\14238\PA-0200551\SU0003940\CDD OK.PDF \MIGRATIONS\H\HARNEY\14238\PA-0200551\SU0003940\EH COND.PDF \MIGRATIONS\H\HARNEY\14238\PA-0200551\SU0003940\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y <br /> (f) The EA may require that an additional soil layer or building pad be placed on the final cover prior to <br /> construction to protect the integrity and function of the various layers of final cover. <br /> j (g)All on site construction within 1,000 feet of the boundary of any disposal area shall be designed and <br /> constructed in accordance with the following, or in accordance with an equivalent design which will <br /> prevent gas migration into the building, unless an exemption has been issued: <br /> 0)a geomembrane or equivalent system with low permeability to landfill -as shall be <br /> installed between the concrete floor slab of the building and subgrade; <br /> (2)a permeable layer of open graded material of clean aggregate with a minimum <br /> thickness of 12 inches shall be installed between the geomembran e and the subarade or <br /> slab; <br /> (3)a Reotextile filter shall be utilized to prevent the introduction of fines into the <br /> permeable layer; <br /> (4) perforated venting pipes shall be installed within the permeable layer, and shall be <br /> designed to operate without clogging- <br /> (5)the venting pipe shall be constructed with the ability to be connected to an induced <br /> draft exhaust system, <br /> (6)automatic methane gas sensors shall be installed within the permeable gas layer, and <br /> inside the building to trigger an audible alarm when methane gas concentrations are <br /> detected; and <br /> (7)periodic methane gas monitoring shall be conducted inside all buildin-s and <br /> underground utilities in accordance with Article 6. of Subchapter 4 of this chapter <br /> (section 20920 et seq.), <br /> Vote: <br />
The URL can be used to link to this page
Your browser does not support the video tag.