Laserfiche WebLink
a�rN SAN JOAQUIN COUNTY <br /> �:;.•• <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 304 E Weber Avenue P Floor Stockton - CA 95202-2708 <br /> (209)468-3420 -Fax:(209)464-0138 - Web:www.co.san-joaquin.ca.us/ehd <br /> `'- 6 REQUIREMENTS CHECKLIST COMMENTS - <br /> I <br /> i <br /> SITE LOCATION: 16100 E. HARNEY LANE, LORI, CA PA#: 03-638 (UP) <br /> REPoRT DATE: 313105 <br /> Section Comments <br /> Domestic water well results for DBCP (dibromochloropropane) were .984 UgIL or (ppb) <br /> parts per billion, which significantly exceeds the state adopted standard of .2ppb. in public <br /> 4.2 drinking water. There was no discussion of mitigation measures included within the body of <br /> the report. As a result of these findings, the EHD has sent the applicant/owner a letter which <br /> provides guidance and alternatives for mitigation. The proposed use for the well water may <br /> lace the waters stem into the public waters stem category. <br /> The site-plan submitted by the applicant is different than the site-plan submitted within <br /> NOA's report Plate 1. The site-plan submitted by the applicant does not demonstrate the <br /> 6.7-6.8 proposed septic area, instead it is all proposed parking map was dated 1212102 but <br /> submitted on 12/7/05. SJC Sewage Standards and land-use conditions require that the <br /> "leach field area must be used for that specific purpose only and in addition the leach field <br /> shall be barricaded so it cannot be driven over, parked on, or used for storage area". <br /> Revise site plan and submit in an addendum. <br /> LI-t <br /> v s �f" o��r � � � # � —� w I`I1n �fll i <br /> I V � o <br /> EHD 26-02-003 Page 3 of 3 Soil Suitability Checklist <br /> 7/14/2003 <br /> 1 <br />