Laserfiche WebLink
i <br /> TABLE 3 <br /> SOIL VAPOR EXTRACTION <br /> PILOT TESTING DATA <br /> SITE ASSESSMENT REPORT <br /> UNDERGROUND STORAGE TANK SITE <br /> JACKPOT FOOD MART <br /> LOCKEFORD, CALIFORNIA <br /> Well W-2 Data <br /> Influent Influent Background Influent Effluent <br /> Time Pressure Temperature Flow hate Flow Rete Flow Rate Concentration Concentration Concentration <br /> (hh mm) (in Hg) (OF] (% full scale) (acfm) (scfm) (ppm) (ppm) (ppm} <br /> 605 PM 45 61 116 1358 1189 220 6000 440 <br /> 610 PM 45 63 115 1352 1179 160 5800 240 <br /> 615 PM 45 63 112 131 6 1148 280 6100 400 <br /> 6 20 PM 45 63 113 132 8 115 9 330 5200 500 <br /> 625 PM 45 63 110 1293 1128 370 5000 650 <br /> 6 30 PM 45 63 109 128 1 1 1 1 8 140 5400 420 <br /> 6 35 PM 1 45 63 112 131 6 1148 230 5500 520 <br /> Averages 45 63 112 132 1 115 3 24 7 557 1 453 <br /> Notes <br /> 2 inch-diameter Wel;s W 4, W-5, and W 6 were opened one at a time during testing, and vacuums were detected at each well <br /> Vacuums were also detected in Wells W 2 and W 3 during testing <br /> I <br /> %V 91 634 TABLES LOCKEFORD�LOCKSVE XLS 14,281831 Page 2 of 3 CanoweEnvlronmental <br />