Laserfiche WebLink
EXCELCHEM <br /> ENVIRONMENTAL LABS <br /> 500 Giuseppe Court, Suite 9 0 <br /> Roseville, CA 95678 <br /> Phone#: (916) 773-3664 Fax#: (916) 773-4784 <br /> 1 ANALYSIS REPORT <br /> Attention: Mr. John Bower Date Sampled : 12-19-96 <br /> Secor Date Received: 12-19-96 <br /> 1787 Tribute Rd., Suite C BTEX Analyzed: 12-26,31-96 <br /> Sacramento, CA 95815 TPHg Analyzed: 12-26,31-96 <br /> Matrix: Water <br /> Project : Jo710-001-01 L00O2 <br /> TRAE OIL-Lockeford, CA <br /> Ethyl- Total <br /> Benzene Toluene benzene Xylenes TPHg <br /> PPB PPB PPB PPB PPB <br /> Reporting Limit-. 0.5 0.5 0.5 0.5 50 <br /> SAMPLE <br /> Laboratory identification: <br /> MW-2 3.7 1.2 1.6 8.3 175 <br /> W1296294 <br /> MW-4 4.9 0.6 ND 0.7 284 <br /> W1296296 <br /> MW-5 9.6 0.9 ND 1.5 122 <br /> W1296297 <br /> MW-6 45.5 45.2 7.5 124 515 <br /> W1296298 <br /> MW-7 ND ND ND ND ND <br /> W1296299 <br /> ppb--Parts per billion—ug1L=micrograms per liter <br /> ND=Not detected. Compound(s)may be present at Concentrations below the reporting limit. <br /> ANALYTICAL PROCEDURES <br /> BTEX-- Besuene, toluene, etbylbenzene, and total xylene isomers (8TEX) are analyzed by using EPA Method 602 which utilizes a gas <br /> chromatograph(Gc)equipped with a photoionization detector(PID). <br /> TPHg—Total petroleum hydrocarbons as gasoline(low-to-medium boiling points)are analyzed by using modified EPA Method 8015,which utilizes a <br /> GC equipped with an FID. <br /> 01-03-97 <br /> ratory Representative Date Reported <br /> EXCELCHEM ENVIRONMENTAL LABS tSCERTIFIED BYTHESTATEOFCALIFORN<A <br /> DEPARTMENT OF HEALTH SERVICES ASA t-IAZARDOt1S WASTETESTINC LABORATORY <br />