Laserfiche WebLink
EXCELCHEIA <br /> • ENVIRONMENTAL LABS <br /> rw <br /> 500 Giuseppe Court, Suite 9 <br /> Roseville, CA 95678 <br /> Phone# (916) 773-3664 Fax# (916) 773-4784 <br /> ANALYSIS REPORT <br /> Attention Mr John Bower Date Sampled 03-19-98 <br /> Secor Date Received 03-20-98 <br /> 9912 Business Park Dr , Ste 100 BTEX Analyzed 03/23,24/98 <br /> Sacramento, CA 95827 TPHg Analyzed 03/23,24/98 <br /> Project 7G 005-001-01/Time Oil Matrix Air <br /> Ethyl- Total <br /> Benzene Toluene benzene Xylenes TPHg <br /> PPMV PPMV PPMV PPMV PPMV <br /> Reporting lAr iit 05 0 5 0 5 0 5 20 <br /> SAMPLE ID <br /> Laboratory ID <br /> INF-W-7 903 8 5 5 6 14 6 2670 <br /> A0398345 <br /> 1NF-W-4 922 199 374 199 3130 <br /> A0398346 <br /> INF-W-2 357 43 272 42 7240 <br /> A0398348 <br /> nWW=milligrams per cubic meter <br /> ND=Not detected. Compound(s)may be present at concentrations below the reporting lint. <br /> ANALYTICAL PROCEDURES <br /> BTEX--Benzene,toluene,ethylbenzene,and total xylene Isomers(BTEX)are analyzed by using modified EPA Method 8020 which utilizes a <br /> gas chromatograph(GGA equipped with a photoiontzation detector(PID) <br /> TPHg--Total petroleum hydrocarbons as gasoline(low-to-medium boiling points)are analyzed by using modified EPA Method 8015,which <br /> utilizes a GC equipped with an FID <br /> 03-24-98 <br /> La ora ry Representative Date Reported <br /> • <br /> EXCELCHFNI FNVIRONMENTAL LABS IS CERTIFIED BY THF STATE OF CALIFORNIA <br /> DEPA RT7,Mr T OF HEALTH SERVICES AS A HAZARDOUS K ASIS TESTING LABORATORY <br /> (Certification Na 2119) <br /> 2 <br />