Laserfiche WebLink
I <br /> I3.0 GROUNDWATER DEPTH AND GRADIENT <br /> GeoAudit measured the depth-to-groundwater at the site in January, February and May <br /> 1994 The depth to groundwater ranged from approximately 72 to 73 feet The gradient <br /> ranged from 0 003 ft/ft to 0 0075 ft/ft Groundwater flow direction was directed southwest <br /> The gradients calculated by GeoAudit are more shallow than the previous gradient of 0 05 <br /> Ift/ft directed westward (November 1992) as calculated by NGA <br /> 4.0 SCOPE OF WORK <br /> I <br /> 4.1 Vapor test <br /> Low concentrations of TPH were detected in soil samples collected from beneath the USTs <br /> at the time of removal 1990, additional soil was removed from the UST excavation at this <br /> time However, the PHS/EHD has no record of confirmatory sampling Slotted 4-inch PVC <br /> casing was installed at the bottom of the excavation Approximately 5 inches of pea gravel <br /> were placed across the bottom of the excavation and covered with plastic sheeting The new <br /> UST's were then installed on top of the plastic sheeting <br /> To determine if petroleum hydrocarbons still remain beneath the USTs, we propose to <br /> Iperform a limited vapor extraction test A regenerative blower will be used to apply a <br /> vacuum to the vapor piping Air samples will then be collected and analyzed <br /> 42 Extended Purge <br />' Low concentrations of TPH as gasoline continue to be detected in water samples from <br /> MW-2 No petroleum hydrocarbons were detected in any other samples from the May 1994 <br /> monitoring event, indicating a limited extent of petroleum hydrocarbons in groundwater A <br /> submersible pump will be used to purge approximately 500 to 1,000 gallons of water from <br /> MW-2 A regenerative blower will be used to apply a vacuum to the well head during <br /> pumping A negative pressure applied to the well head has been shown to increase well <br /> recharge and pumping rates <br /> 5 0 PROCEDURES <br /> 51 Vapor Test <br /> The following procedures will be followed to perform the limited vapor extraction test <br /> beneath the UST's <br /> 1 Notifythe EHD 48 hours nor to commencement of any work <br /> P <br /> 0-1111-1 Alda S—1*1 5 <br /> laeW-1i Boon.�p119 9060 5 <br /> I <br />