Laserfiche WebLink
'Y 1—NO <br /> - <br /> .� .. a xi.• <br /> July 16, 1987 AGS Job No. 87048-1 <br /> Beacon Station #675 - Lockeford, CA <br /> The calculations presented in Table 1 were used to estimate the <br /> ground water potentiometric surface across the site. The <br /> contours of this surface are shown on the Ground Water <br /> Potentiometric Surface Map, Plate 2A. The contours indicate a <br /> gradient of approximately 0.33 feet per 100 feet (17.6 feet per <br /> mile) and implies ground water flow predominantly toward the west <br /> (S61W). No data regarding flaw rates are available at this time. <br /> ANALYTICAL RESULTS <br /> Twelve soil samples retrieved from the unsaturated zone were <br /> analyzed for total volatile hydrocarbons and hydrocarbon <br /> constituents (benzene, ethylbenzene, toluene, and xylene - HETX) <br /> using gas chromatography with flame ionization detection <br /> (Environmental Protection Agency (EPA) Method 8020) . Four water <br /> samples were analyzed for total volatile hydrocarbons and <br /> hydrocarbon constituents using gas chromatography with photo- and <br /> flame ionization detection (EPA Method 602) . The results of the <br /> chemical analyses are presented in Table 2 and in the Appendix of <br /> this report. <br /> 9 <br /> �� ,4,®plied G°eoSy.�te�ss <br />