Requirements for Installing the System (cont.).
<br /> MSecure the pressure distribution pipe to the top of this
<br /> chamber as in Step 1.
<br /> MContinue interlocking the chambers and connecting
<br /> lateral pipe until the trench is completed.
<br /> IsCap the pipe just before the end of the last chamber
<br /> Secure the pipe to the top of the chamber with a plastic pipe and attach the end plate to the unit.
<br /> hanger or nylon strap. NOTE. If cleanout extensions are required, cut a hole in the
<br /> end plate through which the pipe will extend. Add a 90°
<br /> •
<br /> Lift and place the next chamber onto the previous one elbow to the pipe so it reaches the soil's surface.
<br /> at a 450 angle. Line up the hook on the center end and
<br /> lower it to the ground, engaging the interlocks.
<br /> Requirements for Covering the System.
<br /> Before backfillif the system must be inspected by a
<br /> health official or by such other official as state and © Backfill the system by pushing the cover onto the
<br /> local law may require. units. Keep a minimum of 12° of compacted cover over the
<br /> chambers before driving across the system.
<br /> 0 Fill the sidewall area with fill material. Be sure the fill
<br /> covers the louvers. NOTE. Do not drive across the system while backfilling in
<br /> © Pack down the fill by walking along the edges of the sand, since sand does not give adequate structural support.
<br /> chambers. This step is important in assuring correct struc- 0 It is best to mound several extra inches of sail over the
<br /> tural support. In wet or clay soil, do not walk in the sidewalls. finished grade to allow for settling and to ensure that runoff
<br /> water is diverted away from the system. The site should also
<br /> be seeded or sodded to prevent erosion.
<br /> INFILTRATOR SYSTEMS, INC.STANDARD LIMITED WARRANTY FOR SEPTIC PRODUCTS
<br /> (a) The structural integrity of each chamber and end plate manufactured by Infiltrator(collectively referred to as"Units'),when installed and operated in a leachfield of an"
<br /> onsite septic system in accordance with Infiltrator's installation instructions,is warranted to the original purchaser('Holder")against defective materials and workmanship
<br /> for one year from the date upon which a septic permit is issued for the septic system containing the Units;provided,however,that if a septic permit is not required for the
<br /> septic system by applicable law,the one(1)year warranty period will begin upon the date that installation of the septic system commences. In order to exercise its war-
<br /> ranty rights,Holder must notify Infiltrator in writing at its corporate headquarters in Old Saybrook,Connecticut within fifteen(15)days of the alleged defect.Infiltrator will
<br /> supply replacement Units for those Units determined by Infiltrator to be defective and covered by this Limited Warranty. Infiltrator's liability specifically excludes the cost
<br /> of removal and/or installation of the Units.
<br /> (b)THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH(a)ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS,
<br /> INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
<br /> 0) The Limited Warranty does not extend to incidental,consequential,special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages,
<br /> including loss of production and profits,labor and materials,overhead costs,or other losses or expenses incurred by the Holder or any third party. Specifically excluded
<br /> from Limited Warranty coverage are damage to the Units due to ordinary wear and tear,alteration,accident,misuse,abuse or neglect of the Units;the Units being sub-
<br /> jected to vehicle traffic or other conditions which are not permitted by the installation instructions;failure to maintain the minimum ground covers set forth in the installation
<br /> instructions;the placement of improper materials into the system containing the Units;failure of the Units or the septic system due to improper siting,improper sizing,
<br /> excessive water usage,improper grease disposal,or improper operation;or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails
<br /> to comply with all of the terms set forth in this Limited Warranty.
<br /> Further,in no event shall Infiltrator be responsible for any loss or damage to the Holder,the Units,or any third party resulting from installation or shipment,or from any
<br /> product liability claims of Holder or any third party. For this Limited Warranty to apply,the Units must be installed in accordance with all site conditions required by state
<br /> and local codes;all other applicable laws;and Infiltrator's Installation instructions.
<br /> (d) No representative of Infiltrator has the authority to change this Limited Warranty in any manner whatsoever,or to extend this Limited Warranty. No warranty applies to
<br /> any party other than the original Holder.
<br /> The above represents the standard Limited Warranty offered by Infiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of
<br /> Units should contact Infiltrator's corporate headquarters in Old Saybrook,Connecticut,prior to such purchase,to obtain a copy of the applicable warranty,and should
<br /> carefully read that warranty prior to the purchase of Units.
<br /> Distributed By:
<br /> 11012109 a •
<br /> O
<br /> SYSTEMS INC
<br /> Environmental Onsite Wastewater Solutions" U.S.Patents:4,759.661:5,017,041:5.156438;5.336,017;5,401,116;5.401,459;
<br /> 5.511,903:5.716,163.5.588,778;5.839,844
<br /> P.O. Box 768 6 Business Park Road Old Saybrook,CT 06475 Canadian Patents:1,329,959;2.004.564 Other patents pending.
<br /> 860-577-7000 FAX 880.577-7001 Infiltrator,Equalizer,and SidaWinder are registered trademams of Infiltrator Syatems Inc.
<br /> Infiltrator is a.registered trademark in France.Infiltrator Systems,Inc.is a registered
<br /> vrww.infiltratorsystems.com trademark in Mexico Contour,MicroLeaching,PWyTuff,Snapt-ock,ChamberSpacer.
<br /> 1-800-221-4436 PosiLock,and OcikPlay are trademarks of Infiltrator Systems Inc.
<br /> 02001 Infiltrator Systems Inc. Printed in U.S.A. A030401AG-t
<br />
|