Laserfiche WebLink
Requirements for Installing the System (cont.). <br /> MSecure the pressure distribution pipe to the top of this <br /> chamber as in Step 1. <br /> MContinue interlocking the chambers and connecting <br /> lateral pipe until the trench is completed. <br /> IsCap the pipe just before the end of the last chamber <br /> Secure the pipe to the top of the chamber with a plastic pipe and attach the end plate to the unit. <br /> hanger or nylon strap. NOTE. If cleanout extensions are required, cut a hole in the <br /> end plate through which the pipe will extend. Add a 90° <br /> • <br /> Lift and place the next chamber onto the previous one elbow to the pipe so it reaches the soil's surface. <br /> at a 450 angle. Line up the hook on the center end and <br /> lower it to the ground, engaging the interlocks. <br /> Requirements for Covering the System. <br /> Before backfillif the system must be inspected by a <br /> health official or by such other official as state and © Backfill the system by pushing the cover onto the <br /> local law may require. units. Keep a minimum of 12° of compacted cover over the <br /> chambers before driving across the system. <br /> 0 Fill the sidewall area with fill material. Be sure the fill <br /> covers the louvers. NOTE. Do not drive across the system while backfilling in <br /> © Pack down the fill by walking along the edges of the sand, since sand does not give adequate structural support. <br /> chambers. This step is important in assuring correct struc- 0 It is best to mound several extra inches of sail over the <br /> tural support. In wet or clay soil, do not walk in the sidewalls. finished grade to allow for settling and to ensure that runoff <br /> water is diverted away from the system. The site should also <br /> be seeded or sodded to prevent erosion. <br /> INFILTRATOR SYSTEMS, INC.STANDARD LIMITED WARRANTY FOR SEPTIC PRODUCTS <br /> (a) The structural integrity of each chamber and end plate manufactured by Infiltrator(collectively referred to as"Units'),when installed and operated in a leachfield of an" <br /> onsite septic system in accordance with Infiltrator's installation instructions,is warranted to the original purchaser('Holder")against defective materials and workmanship <br /> for one year from the date upon which a septic permit is issued for the septic system containing the Units;provided,however,that if a septic permit is not required for the <br /> septic system by applicable law,the one(1)year warranty period will begin upon the date that installation of the septic system commences. In order to exercise its war- <br /> ranty rights,Holder must notify Infiltrator in writing at its corporate headquarters in Old Saybrook,Connecticut within fifteen(15)days of the alleged defect.Infiltrator will <br /> supply replacement Units for those Units determined by Infiltrator to be defective and covered by this Limited Warranty. Infiltrator's liability specifically excludes the cost <br /> of removal and/or installation of the Units. <br /> (b)THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH(a)ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, <br /> INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. <br /> 0) The Limited Warranty does not extend to incidental,consequential,special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, <br /> including loss of production and profits,labor and materials,overhead costs,or other losses or expenses incurred by the Holder or any third party. Specifically excluded <br /> from Limited Warranty coverage are damage to the Units due to ordinary wear and tear,alteration,accident,misuse,abuse or neglect of the Units;the Units being sub- <br /> jected to vehicle traffic or other conditions which are not permitted by the installation instructions;failure to maintain the minimum ground covers set forth in the installation <br /> instructions;the placement of improper materials into the system containing the Units;failure of the Units or the septic system due to improper siting,improper sizing, <br /> excessive water usage,improper grease disposal,or improper operation;or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails <br /> to comply with all of the terms set forth in this Limited Warranty. <br /> Further,in no event shall Infiltrator be responsible for any loss or damage to the Holder,the Units,or any third party resulting from installation or shipment,or from any <br /> product liability claims of Holder or any third party. For this Limited Warranty to apply,the Units must be installed in accordance with all site conditions required by state <br /> and local codes;all other applicable laws;and Infiltrator's Installation instructions. <br /> (d) No representative of Infiltrator has the authority to change this Limited Warranty in any manner whatsoever,or to extend this Limited Warranty. No warranty applies to <br /> any party other than the original Holder. <br /> The above represents the standard Limited Warranty offered by Infiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of <br /> Units should contact Infiltrator's corporate headquarters in Old Saybrook,Connecticut,prior to such purchase,to obtain a copy of the applicable warranty,and should <br /> carefully read that warranty prior to the purchase of Units. <br /> Distributed By: <br /> 11012109 a • <br /> O <br /> SYSTEMS INC <br /> Environmental Onsite Wastewater Solutions" U.S.Patents:4,759.661:5,017,041:5.156438;5.336,017;5,401,116;5.401,459; <br /> 5.511,903:5.716,163.5.588,778;5.839,844 <br /> P.O. Box 768 6 Business Park Road Old Saybrook,CT 06475 Canadian Patents:1,329,959;2.004.564 Other patents pending. <br /> 860-577-7000 FAX 880.577-7001 Infiltrator,Equalizer,and SidaWinder are registered trademams of Infiltrator Syatems Inc. <br /> Infiltrator is a.registered trademark in France.Infiltrator Systems,Inc.is a registered <br /> vrww.infiltratorsystems.com trademark in Mexico Contour,MicroLeaching,PWyTuff,Snapt-ock,ChamberSpacer. <br /> 1-800-221-4436 PosiLock,and OcikPlay are trademarks of Infiltrator Systems Inc. <br /> 02001 Infiltrator Systems Inc. Printed in U.S.A. A030401AG-t <br />