,- . %we '-.00'.i <br /> Peaking factors for users on septic tanks vary with usage during the hour of the day, and day of the <br /> week. Peak hourly rates are associated with normal working hours. The ratio of the peak day to the <br /> average day can vary from 1.5 to >5, depending upon the usage. However, peaking factors are not as <br /> relevant since the effluent pump will dose on demand. A peaking factor of 2.5 (average between 0 <br /> and 5)will be used in the calculation below: <br /> Septic Tank Hydraulic Detention Time <br /> Detention Time=4.000 gal septic tank capacity x 0.70(30%volume lost to sludee/scum accumulation) <br /> 2.5 (Peaking Factor)x 1,000 gals/day ADF <br /> Detention Time= 1.12 days. The minimum acceptable detention time is 1.0 days. <br /> Filter Bed Area <br /> The filter bed area is normally calculated under Section 8.7 of the San Joaquin County Sewage <br /> Standards and EHD Document 42-01-004: Calculation Requirements for Commercial Septic <br /> Systems: <br /> Base Tank Capacity (BTC) = 1,200 gals <br /> Lineal Feet of Leachline (LFLL)= 1,200 BTC + 1,000 ADF x 0.20 SF =440 LFLL <br /> Filter Bed Area=440 x 3 = 1,320 square feet. The filter bed area should be square in area: <br /> 40 ft x 40 ft= 1,600 sq. ft. <br /> The filter bed area should also correspond with the percolation, and more particularly, the infiltration <br /> test results. As referenced above, the application rate correlated with the infiltration test results, is <br /> 0.857 gals/ftz/day. Using the ADF of 1,000 gpd_0.857 gals/ft2/day= 1,167 sq. ft filter bed. <br /> Therefore, the filter bed size of 1,600 sq. ft. based on the Sewage Standards is applicable. <br /> Wastewater Disposal System Parameters and Appurtenances <br /> Zabel or Orenco Filtration from second septic tank to filter bed(EHD Requirement) <br /> Duplex pump system (EHD Requirement) <br /> Flowmeter on effluent pumped to filter bed(EHD Requirement) <br /> Distal end clean-outs on each lateral (EHD Requirement) <br /> As-Builts of entire system by installer after installation(EHD Requirement) <br /> Monitoring of effluent with monitoring ports or wells within, or on the perimeter of the filter bed <br /> area. Observation tubes: 4" PVC Tee at soil/effluent interface with a 4" riser flush with the grass <br /> surface and a screw-type cap. (EHD Requirement) <br /> 1.5 inches of peat at soil/effluent interface (EHD Requirement) <br /> Filter Bed Area=40 ft north/south and 40 ft east/west= 1,600 sq. ft. Filter bed should be at <br /> grade with surrounding soil surface. <br /> Laterals: 7 laterals, Sch. 40 PVC, 1.5" nominal diameter, 5/32" orifice directed at 12 o'clock with <br /> 3" PVC orifice shield Zabel Part No. PDS-ZOS-125/150, 4.0 ft orifice spacing, each lateral 36 ft <br /> long. Orifice Discharge Rate: 5/32" with 5' residual head=0.64 gpm <br /> 36 ft-4 ft= 9 orifices/lateral x 0.64 gpm/orifice= 5.8 gpm/lateral <br /> Page -9- <br /> Ckesney Cxwdting <br />