My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011282 SSCRPT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4125
>
2600 - Land Use Program
>
PA-1700057
>
SU0011282 SSCRPT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:05 AM
Creation date
9/6/2019 9:59:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSCRPT
RECORD_ID
SU0011282
PE
2622
FACILITY_NAME
PA-1700057
STREET_NUMBER
4125
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215-
APN
15728108
ENTERED_DATE
3/24/2017 12:00:00 AM
SITE_LOCATION
4125 E MAIN ST
RECEIVED_DATE
3/23/2017 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\4125\PA-1700057\SU0011282\SURSUB RPT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Preliminary Screen for Potential Vapor Intrusion Conditions Matrix <br /> VELASQUEZ <br /> WKA No. 8237.01 <br /> ' Phase I ESA Preliminary Screen for Potential Vapor Intrusion Conditions(pVIC)matrix includes a(1)Search Radius <br /> Test, (2) Chemicals of Concern Test(COC), and(3) a Critical Distance Testlri. <br /> (1) Search Radius Test: Are there any known or suspect contaminated sites in the primary area of concern within the <br /> corresponding search radii? (see Table attached Table 1). <br /> ' Y Yes ❑ No if No,then screening for a pVIC is complete and no pVIC currently exists,go to#4. If Yes,then: <br /> (2) Chemicals of Concern[21 Test: Are COC likely to be present within the area of concern for those known or suspect <br /> ' contaminated sites identified based on the Search Distance Test? <br /> ' X Yes ❑ No If No,then screening for a pVIC is complete and no pVIC currently exists,go to#4. If Yes,then: <br /> If Yes, check all COC that apply on attached Table 2. <br /> ' (3) Critical Distance Test: A plume test to determine whether or not COC in the contaminated plume(s)may be within <br /> the critical distance. <br /> ' (3a)Is information related to the comaminated(s)plume available(i.e. isoconcentration maps,site drawings, etc.)? <br /> Yes ❑ No <br /> (3b)If No,then screening for a pVIC is complete and no pVIC currently exists, go to#4. If Yes,then: <br /> ' (3c)Is the site less than 100 feet to the nearest edge of a contaminated[non-petroleum hydrocarbon] plume(s)? <br /> XYes ❑ No <br /> ' (3d)Is the site less than 30 feet to the nearest edge of a dissolved petroleum hydrocarbon plume(s)? <br /> XYes ❑ No <br /> C <br /> If the distance from the nearest edge of a contaminated plume to the nearest existing or planned structure on the site is less <br /> than 100 feet for non-petroleum hydrocarbon COC,or less than 30 feet for dissolved petroleum hydrocarbons,then it is <br /> presumed that a pVIC currently exists beneath the site. If the distance from the nearest edge of the contaminated plume is <br /> greater than or equal to 100 feet for non-petroleum hydrocarbons,or 30 feet for dissolved petroleum hydrocarbon chemicals <br /> ' of concern,then it is presumed unlikely that a pVIC currently exists beneath the site. <br /> (4) Is it likely that a pVIC currently exists beneath the site? <br /> ' Jdl Yes ❑ No If Yes, then recommend performing a full scope VIC assessment according to ASTM E 2600-08. <br /> fit]Based on guidance presented in to ASTM E 261 Standard. <br /> (2)Cherricsrs)o(wddern(COC): See attaGieE table for typical chemicals of condom(as presented in Appendix x8 of to ASTM E 2800.08 Standard). <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.