Laserfiche WebLink
1 - <br /> modular,underground, extended aeration treatment units will be used. For reference,-a general <br /> diagram of this type of unit is presented in Appendix D. <br /> Three separate and independent wastewater treatment units are proposed: 1) one unit for <br /> facilities associated with Phase I of development; 2) one unit for the restaurant within Phase 2; <br /> and 3) one unit for the hotel within Phase 2. The units will be configured in parallel, and each <br /> unit will be equipped with a compressor/blower system and aeration controls. The wastewater <br /> treatment capacity of each unit will be approximately 5,000 gpd. <br /> 1.3 Drip Dispersal Area <br /> Treated wastewater will flow into a drip dispersal area. Sizing calculations for the proposed <br /> l dispersal area are presented in Appendix C. In all of the sizing calculations, a wastewater <br /> application rate of 0.2 gpd/ft2 was assumed and 100 percent reserve capacity was included. <br /> For Phase 1, the required dispersal area will be approximately 31,500 ft2,including reserve <br /> capacity. The required area for dispersal of wastewater from Phase 1 and Phase 2 developments <br /> combined, with reserve capacity, is 108,800 ft2. The following minimum required setbacks will <br /> be applied during facilities layout and site design: 10 ft from dispersal field to property <br /> boundaries, 25 ft from dispersal field to buildings, and 100 ft from dispersal field to wells. <br /> y 2.0 PROPOSED IMPLEMENTATION STRATEGY <br /> i <br /> Discussions of proposed construction phasing and incremental permitting efforts are presented <br /> below. <br /> 2.1 Phased Construction <br /> ' Phased construction is proposed for the wastewater treatment units and dispersal area. Treatment <br /> and dispersal infrastructure for Phase 1 of KMC development will be constructed initially. The <br /> y Phase 1 estimated wastewater flow,proposed treatment unit capacity, and required dispersal area <br /> are approximately 3,150 gpd, 5,000 gpd, and'31,500 ft2, respectively. <br /> Wastewater treatment and dispersal infrastructure for Phase 2 of KMC development will be <br /> divided into two components. The first component of Phase 2 will include infrastructure for the <br /> restaurant within Phase 2. The estimated wastewater flow, proposed treatment unit capacity, and <br /> required dispersal area for this element of Phase 2 are approximately 2,880 gpd, 5,000 gpd, and <br /> 28,800 ft2,respectively. The second component of Phase 2 will include infrastructure for the <br /> hotel. The estimated wastewater flow, proposed treatment unit capacity, and required dispersal <br /> } area for this element of Phase 2 are approximately 4,850 gpd, 5,000 gpd, and 48,500 ft2, <br /> respectively. A summary of the proposed phased construction of wastewater treatment and <br /> dispersal facilities is presented in Table 3. <br /> 5 <br /> ti <br /> KMC—Wastewater Pre-Application Information 3 MTB015600 <br /> September 2007 n:lmtb02560OVeports4astewater pre applfinal 091907,doc <br />