Laserfiche WebLink
I <br /> SITE PLAN CHECK LIST <br /> SITE PLAN CHECK LIST <br />. I <br /> • Size: The Site Pian must be drawn on minimum 1$"x 24"reproducible material. <br /> I <br /> North Arrow, Date and Scale: Use an engineer's scale(i.e., 1"to 2D'or 1"to 40',"north"should be pointing towards the top of the page. 0, preferred}. The direction of <br /> • Streets and Easements: Location and names of all streets and easements bordering on the property with <br /> access details. <br /> Property Lines: All property lines or boundary lines of the parcel with dimensions. <br /> • i <br /> Vi - i <br /> ernity Map. �A vicinity map showing the location of the property in relation to surrounding streets. <br /> Variance Request: The requested Variance must be clearly identified-and dimensioned. <br /> IM <br /> Existing and Proposed Development: All"existing structures (labeled'existing')and any Proposed structures <br /> (labeled 'proposed')with dimensions,square footage and distances from other structures and property lines. <br /> Any existing structures planned for removal should be shown with dashed lines. The <br /> should be labeled on each structure. use and number of floors <br /> !i <br /> • Parking and Driveways: The location, dimensions and surface material of all existing and proposed parking <br /> driveways. Calculations indicating the number of required spaces must be shown. (Refer to'County Parking <br /> Lot Standards'). P ng and <br /> Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 1 1 <br /> Proposed development, Wells must be meet the following_setbacfcs: 50'of the <br /> 5'from structures; <br /> 50'from septic tanks; <br /> 100'from leach lines; <br /> 150'from sumps or seepage pits,and <br /> 10'from Pr6perty fines. t <br /> Sewers and Septic Tanks: The location of the sewer outlet, public sewer hook-up, or exist <br /> sewage disposal systems avid any off-site sewage disposal systems within 150 of the property, <br /> Septic tanks must meet the following setbacks:g Ing and proposed <br /> - 5'from pro � � P p rn`' <br /> P !?e1'tY lines, structures,driveways and swimming pools, <br /> - 50'from water wells. <br /> Leach lines must meet the following setbacks: <br /> - 10'from structures, driveways and swimming pools; <br /> - 1 00'from wells, streams and waterways, <br /> - 5'to 75'from Property lines depending on zoning or the location of septic systems on adjoining properties <br /> (this requirement also applies to seepage pits). <br /> I` <br /> Storm Drainage:ll The location of.existing and proposed storm drainage facilities(check with Engineering staff <br /> regarding design criteria). If subject to flooding, the 100-year flood elevations must be shown. Indicate any <br /> unusual topographic features of the site(e.g. steep slopes, or-drainage courses). Grading and contours need to <br /> be spawn, <br /> • I� <br /> Landscaping: The location of existingand proposed <br /> trees to be removed). Calculation inicatinthe percentaglandscaping <br /> of thand <br /> netts to aees Grea t'oro be landscaped must be any <br /> shown. (Refer t County Landscaping Standards). <br /> 66 <br /> Signs, Fences, Storage and Trash Enclosures: The location of and height of all existing and proposed signs <br /> and fences and the location and dimensions of all.o Den and/or enclosed stora a and trash rece tacles. <br /> II SITE PLANS MUST BE COMPLETE AND LEGIBLE- <br /> Before <br /> EGIBLEBefore applying, Ii <br /> check your Site Plan to make sure that it contains all of the information cited above. You are <br /> encouraged to have one of our counter staff review your draft Site Plan prior to having copies run. <br /> Faint Prints and fight blue lines will not be accepted because they cannot be reproduced <br /> or microfilmed. <br /> I <br /> F10EVSVQP12nning APPlicaton FormslVariance.doc. Revised 8- <br /> ( 1"4) Page 7 of 7 <br /> ' IE <br /> ;I <br /> �i <br />