My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0006677 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
12687
>
2600 - Land Use Program
>
PA-0700315
>
SU0006677 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:32:39 AM
Creation date
9/6/2019 10:05:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0006677
PE
2631
FACILITY_NAME
PA-0700315
STREET_NUMBER
12687
Direction
S
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19123007
ENTERED_DATE
8/3/2007 12:00:00 AM
SITE_LOCATION
12687 S MANTHEY RD
RECEIVED_DATE
8/2/2007 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MANTHEY\12687\PA-0700315\SU0006677\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IV. WASTEWATER DISPOSAL SYSTEM <br /> OPERATIONAL PARAMETERS <br /> The new septic system for the Blue Rhino Office Trailer will be sized for 150 gpd under EHD <br /> Sewage Standards criteria. This Average Daily Flow (ADF) is based on the premise of one uni-sex <br /> restroom with one low-flow toilet. A filter bed disposal structure is proposed instead of <br /> conventional leachlines to reduce the disposal area footprint. <br /> Septic Tank Sizing <br /> Influent from the Office Trailer will gravity flow into a 1,200 gallon septic tank Effluent from this tank <br /> will gravity to the filter bed as illustrated on the Site Plans. The tank must be pumped on a prescribed <br /> interval basis depending on direct observations of paper and scum accumulation; e.g., every six months to <br /> every three years, depending on sludge/scum accumulation. Peaking factors for septic tanks vary with <br /> usage during the hour of the day,and day of the week. Peak hourly rates are associated with normal <br /> working hours. The ratio of the peak day to the average day can vary from 1.5 to>5, depending upon the <br /> usage. A peaking factor of 2.5 (average between 0 and 5)will be used in the calculation below: <br /> Septic Tank Hydraulic Detention Time <br /> Detention Time= 1,200 gal septic tank capacity x 0.70(30%volume lost to sludge/scum accumulation) <br /> 2.5 (Peaking Factor)x 150 gals/day ADF <br /> Detention Time=2.2 days. The minimum acceptable detention time is 1.0 days. <br /> Therefore, a 1,200 gallon septic tank is adequate. <br /> Primary and 100% Replacement Filter Bed Area <br /> The filter bed area is calculated in the procedure described in Section 8.7 of the San Joaquin <br /> County Sewage Standards and EHD Document 42-01-004: Calculation Requirements for Commercial <br /> Septic Systems: <br /> Base Tank Capacity(BTC) = 1,200 gals <br /> Lineal Feet of Leachline(LFLL) = 1,200 BTC + 150 ADF x 0.225 Soil Factor based on a loam soil at <br /> 40 inches below grade where the soil-effluent interface will occur= 304 LFLL <br /> Filter Bed Area=304 x 3 (Sandy Loam Soil Factor)=912 square feet. The primary filter bed area, as <br /> illustrated on the Siegfried Site Plans, is proposed to be rectangular in area: <br /> 35 ft wide E-W x 40 ft long N-S = 1,400 sq ft available for the primary filter bed area. <br /> The filter bed area also corresponds with the percolation test results. As referenced above, the <br /> application rate correlated with the perc test results of 8.9 min/inch translate to an application rate of <br /> 0.857 gals/ftt/day. Using the ADF of 150 gpd, we find: 150 gpd_ 0.857 gals/ft'/day = 175 sq. ft. <br /> Therefore, the filter bed size of 912 sq ft is adequate based on the test results obtained. The 100% <br /> replacement/reserve area is directly east of the primary filter bed area in the parking area, and also <br /> has 1,400 sq. ft. of available area. <br /> 10 <br /> Chesney Consulting <br />
The URL can be used to link to this page
Your browser does not support the video tag.