Laserfiche WebLink
. ENVIRONMENTAL HEALTH DEPARTMENT <br /> Donna K.H R.E.H.S. SAN JOAQUIN COUNTY <br /> y Unit Supervisors <br /> Director <br /> ctor 304 East Weber Avenue, Third Floor Carl Bor gman,R.E.H.S. <br /> At Olsen,R.E.H.S. Stockton, California 95202-2708 Mike lasW.Huggins,Wilson, <br /> S.,R.D.I. <br /> Douglas W.Wilson,R.E.H.S. <br /> • cq: FOR��P • Program Manager Telephone: (209) 468-3420 Margaret Lagorio,R.E.H.S. <br /> Laurie A.Cotulla,R.E.H.S. <br /> Fax: (209) 464-0138 Robert McClellon,R.E.H.S. <br /> Program Manager ,4 Mark Barcellos,R.E.H.S. <br /> September 3, 2003 <br /> 8� <br /> TO: San Joaquin County <br /> Community Development Department <br /> FROM: San Joaquin County <br /> Environmental Health Department <br /> CONTACT PERSON: Justin Hess,E.H.S. <br /> PHONE NUMBER: (209) 468-3453 <br /> RE: PA-03-399 (SA),Attention: Leanne Mueller <br /> 15933 South Manthey Road, Lathrop <br /> The San Joaquin County Development Title Requirements listed below have been identified as <br /> pertinent to this project. Other requirements may also apply. These requirements cannot be <br /> modified. <br /> A. Environmental Health Department requires a soil suitability/nitrate loading study <br /> incorporating proposed staff and customer use, indicating that the area is suitable for septic <br /> tank usage. This must be performed prior to issuance of building permits (San Joaquin <br /> County Development Title, Section 9-1105.2(d)). A nitrate loading study is required, and a <br /> review fee of$465.00 must be paid at time of submittal to Environmental Health <br /> Department. <br /> The sewage disposal system shall comply with the on site sewage standards of San Joaquin <br /> County prior to approval. A percolation test that meets absorption rates of the manual of <br /> septic tank practice or E.P.A. Design Manual for onsite wastewater treatment and disposal <br /> system is required for each parcel. A permit fee of$93.00 per percolation hole is required. <br /> B. State on revised site plans the maximum number of staff and customers the sewage disposal <br /> system is being designed for. In addition, show on revised plans that the leach field area will <br /> be barricaded so it cannot be driven over,parked on, or used as a storage area. This leach <br /> field area must be used for that specific purpose only, and it cannot contain any underground <br /> utility lines (San Joaquin County Development Title, Section 9-1110.4(c)(5)). <br /> NOTE: Site Plan needs to show septic system for existing home and the 100% designed <br /> replacement area for the proposed office. <br /> Pagel of 2 <br />