SU0006756
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
8853
>
2600 - Land Use Program
>
PA-0700439
>
SU0006756
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:32:42 AM
Creation date
9/6/2019 10:05:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0006756
PE
2633
FACILITY_NAME
PA-0700439
STREET_NUMBER
8853
Direction
S
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
FRENCH CAMP
APN
19320006
ENTERED_DATE
10/3/2007 12:00:00 AM
SITE_LOCATION
8853 S MANTHEY RD
RECEIVED_DATE
10/1/2007 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MANTHEY\8853\PA-0700439\SU0006756\APPL.PDF \MIGRATIONS\M\MANTHEY\8853\PA-0700439\SU0006756\CDD OK.PDF \MIGRATIONS\M\MANTHEY\8853\PA-0700439\SU0006756\EH COND.PDF \MIGRATIONS\M\MANTHEY\8853\PA-0700439\SU0006756\EH PERM.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> op441"- AN JOAQUIN COUNTY , <br /> r. OMMUNITY:DEVELOPMENT DEPARTMENT. . <br /> a`: x <br /> � v • <br /> Melnora <br /> fid.um <br /> .. - S ,f.. <br /> To: Devetoprrtent Sei vices Date: 10719/2007Al <br /> ' <br /> ( tactperson <br /> From: Fire Prevention, Steve Dalton ac Date: 1011912007. <br /> (Contact person) f <br /> Subject: PA-0700439 'a <br /> # (Planning application referral number), <br /> Project SuntPary: Site approval for construction of a trucking facility to consist of 5 buildings apn: 193-200-06,8853 S. $. <br /> Manthey Rd. Silva Trucking French-Camp FD. <br /> The following Uniform Fire Code and Sari Joaquin County Ordinance Code requirements will be applicable and shall be <br /> incorporated in the construction plans before submittal to the Community Development Department for a building permit. <br /> F� a. [] The Fire Prevention Division has reviewed this application and there does not appear to.be any major problems <br /> associated with the proposed project as submitted. <br /> ❑ A complete review at building permit submittal will require compliance with applicable codes and ordinances. <br /> i b. Fire flow and hydrants will be provided for the proposed project by the use of <br /> ❑ 1.)Appendix III-A and IU-B of the California Fire Code. <br /> V 2.)NFPA 1142 of the National Fire Code. <br /> W c- Fire sprinkler systems shall be installed according to Article 10 of the California Fire Code and the appropriate standards <br /> and guides adopted in Chapter 35 of the California Building Code and the California Electrical Code. <br /> d. Fire department access roads shall be in accordance with section 902.2 of the California Fire Code and the standard <br /> adopted by the San Joaquin County Fire Chiefs Association. <br /> ❑ e. This planning application will require a fire access road to be completed before the County Surveyors office will file the <br /> map for record.Please contact Fire Prevention at 209468-3380 to schedule an inspection of the completed road <br /> ❑ f- This project shall comply with the San Joaquin County Development Title Section 9-1150.18,Road Naming <br /> Proceedures.Please contact the Community Development Department at 4.68-2.19.3_to complete this process prior <br /> to requesting Fire Department approval. <br /> ❑� g. Key Boxes:A Knox box shall be installed according to the local fire department's instructions. <br /> �] h Fire extinguishers shall be installed in accordance with California Fire Code, Standard 10-1 of Volume 2. <br /> 0 i. Fire permits may be required prior to occupancy to conduct operations hazardous to life or property C.F.C. 105.2.1 <br /> ❑ j. A technical report to determine the acceptability of technologies, processes, products, facilities, materials, and uses <br /> attending the design,operation or use of the building or premises may be required. (CFC 1103.2.4) <br /> ❑ k, All undeveloped parcels or portions of undeveloped parcels which are created as a result of this planning application <br /> shall remain free of weeds, debris, or any other combustible vegetation such as abandoned orchards or vineyards <br /> throughout the year to the satisfaction of the Fire Jurisdiction Having Authority.(CFC 1103.2.40 <br /> Other: <br /> A fire sprinkler system may be needed in Building 3.A preliminary review with applicant can be scheduled. <br />
The URL can be used to link to this page
Your browser does not support the video tag.