Laserfiche WebLink
's SITE PLAN CHECK LIST <br /> SITE <br /> LAN- <br /> , CHECK LIST <br /> rp <br /> ize: Thesite plan must be drawn on 1S"x 26"reproducible material. <br /> orth Arrow, Date and Scale: Use an engineer's scale(i.e., 1"to 20'or 1"to 40',preferred). The direction of"north"should be <br /> ointing towards the top of the page.treets and Easements: Location and names of all streets and easements bordering on the property with access details. <br /> rope —Lines:-Allexi <br /> dY sting and proposed propertylines or boundary ary Ilnes of the parcel with dimensions. Label each Parcel 1,2,3, <br /> 4,etc.and indicate the net square footage(acreage)of each. <br /> • Vicinity Map: A vicinity map showing the location of the property in relation to surrounding streets. <br /> Names and Signatures: Name,signature,address and telephone number of owner;the name,address and telephone number of <br /> the owner, surveyor or engineer filing the map. <br /> Contour Lines: Contour lines or spot elevation relative to mean sea level datum. <br /> • Dedications: Improvements and easements to be dedicated to the County. <br /> I <br /> • Existing and Proposed Development: All existing structures(labeled'existing')and any proposed structures.(labeled'proposed') <br /> with dimensions,square footage and distances from other structures and existing and proposed property lines. Any existing <br /> structures planned for removal should be shown with dashed lines. The use and number of floors should be labeled on each <br /> structure. <br /> Parking and Driveways: The location,dimensions and surface material of all existing and proposed parking and driveways. j <br /> Water Wells: The location of existing and proposed water wells on-site and any off-site wells within 150'of the proposed <br /> development. Wells must be meet the following setbacks: i <br /> T from structures; <br /> - 50'from septic tanks; <br /> - 100'from leach lines; <br /> 150'from sumps or seepage pits;and <br /> 10'from property lines. <br /> If public water will be utilized,a"will-serve"letter must be submitted from the service provider. <br /> • Sewers and Septic Tanks: The location of the sewer outlet,public sewer hook-up,or existing and proposed sewage disposal <br /> systems including leach field areas and any off-site sewage disposal systems within 150'of the property. <br /> Septic tanks must meet the following setbacks: <br /> - 5'from property lines,structures, driveways and swimming pools; <br /> - 50'from water wells. <br /> Leach lines must meet the following setbacks: ` <br /> 10'from structures,driveways and swimming pools; <br /> - 100'from wells,streams and waterways. <br /> - V to 75'from property lines depending on zoning or the location of septic systems on adjoining properties(this requirement <br /> also applies to seepage pits). <br /> If public sewage disposal will be utilized,a"will-serve"letter must be submitted from the service provider. ; <br /> Storm Drainage: The location of existing and proposed storm drainage facilities(check with Engineering staff regarding design h <br /> criteria). If subject to flooding,the 100-year flood elevations must be shown. Indicate any unusual topographic features of the site <br /> (e.g.steep slopes,or drainage courses)., <br /> Watercourses: The location of existing watercourses and the extent of any levee,with toe and crown indicated. I <br /> Flooding:'The area subject to flood from an intermediate regional flood and depth of flood waters, if applicable. Proposed method <br /> of flood protection if property is subject to inundation from an intermediate regional flood or other flood hazard. <br /> SITE PLANS MUST BE COMPLETE AND LEGIBLE <br /> Before applying, check your Site Plan to make sure that it contains all of the information cited above. You are encouraged to <br /> have one of our counter staff review your draft Site Plan prior to having copies nun. <br /> • Faint prints and light blue fines will not be accepted because they cannot be reproduced or microfilmed. <br /> ---------------------- t <br /> °FMEVSVC71anning Application Formsl Page 7 of 7 <br /> Lot Line Adjustment.doc.(Revised 6-3-03) <br /> i <br />