Laserfiche WebLink
(§ 1.0) INTRODUCTION <br /> This Soil Suitability Study presents the results of my investigation concerning the soil <br /> characteristics and groundwater under the subject property referenced on the Title Page. It was <br /> completed to satisfy the requirements of the San Joaquin County Environmental Health <br /> Department (EHD), specifically: 1.) To create two individual Parcels from this subdivision, 2.) To <br /> determine if the soil underlying the proposed Parcels are acceptable for the proper operation of a <br /> septic system, and 3.) Provide analysis and recommendations based upon the environmental <br /> criteria encountered in this study. This report is in compliance with the requirements for a Soil <br /> Suitability Study under Development Title Section 9-1105.2 Item (d) of the San Joaquin County <br /> Ordinance Codes. <br /> Within the text of this Report, bolded Section (§) numbers are referenced at the beginning of an <br /> applicable sentence, paragraph(s), or Appendices that correspond with the EHD Requirements <br /> Checklist for a Soil Suitability Study. <br /> (§2.0) SUBJECT SITE AND STUDY AREA BACKGROUND INFORMATION <br /> (§. 1, 1.2,2.1) The purpose of this project is to-subdivide an existing 172.81± acre Parce nto <br /> two.Parcels denoted as Parcel 1, which is to be 100.61 net acres, and Parcel 2 which is to qe 72.20 <br /> acres. There are a total of six structures on proposed Parcel 1, and no structures on Par6eL2 as <br /> illustrated on the Tentative Map. The main residential structure address is 11495 Van Allen Road. <br /> The other five structures include two mobile homes, a barn, dairy freestalls/milk barn and an out <br /> building. Individual septic systems serve these structures. A single domestic well serves the <br /> residential structures and another well serves the dairy> ams. Parcel 2 has been prepared to be <br /> planted in almond trees. There is an irrigati6n well near the southeast corner of Parcel 2. This <br /> well will provide irrigation water to the future trees. <br /> (§ 3.7) Parcel orientation is denoted on the Tentative Map, produced by the engineering firm of <br /> Giuliani & Kull of Oakdale. Although there is no proposal to build any additional buildings on the <br /> subject Parcels, any improvement of the Parcels will have to observe all EHD requirements. This <br /> would include a perc test in the location of any proposed effluent disposal area. <br /> (§ 1.1 and 2.1) The subject property is approximately three miles northwest of the city of <br /> Escalon. Surrounding property use consists predominately of agricultural production land, <br /> extremely low density single family homes, ranchettes, and ag buildings. Current zoning is AG <br /> 40, which will not change. Municipal sewer will probably never serve this area, at least not for <br /> several decades. <br /> (§ 4.2) Any of the above land use could create environmental concerns that may be discovered in <br /> the future. As evidenced by the testing of the on-site domestic well and discussed in Section 4.0, <br /> the groundwater nitrate concentrations are comparatively low and the agrichemical Dibromo- <br /> chloropropane (DBCP) is non-existent. <br /> Page -2- <br />