My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0005179 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
4806
>
2600 - Land Use Program
>
PA-0400764
>
SU0005179 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:31:30 AM
Creation date
9/6/2019 10:07:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0005179
PE
2689
FACILITY_NAME
PA-0400764
STREET_NUMBER
4806
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
APN
17916018, 19, &
ENTERED_DATE
7/6/2005 12:00:00 AM
SITE_LOCATION
4806 E MARIPOSA RD
RECEIVED_DATE
7/6/2005 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MARIPOSA\4806\PA-0400764\SU0005179\NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S = snmeicnt <br /> I = Insnfficicnt <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> l❑ ❑/6.1 Site map showing the location,with concise and accurate dimensions of the percolation test holes on the parcel. <br /> I " I ❑ 6.2 The minimum number of shallow and deep percolation tests was performed for each parcel. .7-1' /o¢��(s !P <br /> 6.3 Description of the date,time and protocol used to prepare the test hole,including depth and dimensions of hole, <br /> j ❑ preparation of hole, and depth of water used to presoak(minimum 12 inches). <br /> 6.4 Description of the date,time and condition of the test hole after the 24-hour soak period(hole still intact,hole dry, <br /> / F-1depth to water remaining in hole,etc.) <br /> ❑ 6.5 The test conformed to SJC Policy EHD 02-02(correct depth,diameter,2"gravel,6"water refill,correct readings <br /> � <br /> }� recorded). <br /> `t <br /> I ❑ 6.6 Complete Percolation Test Form(including readings)was provided with REHS verification signature. The rate <br /> EJ6.7 <br /> correctly calculated using the last reading. <br /> r� 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. <br /> �J ❑ 6.8 Discussion of percolation rates in relation to the type,size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: �T �f <br /> Reviewed Date: /9 -cg <br /> EHD 26-02-003 Page 2 of 3 - <br /> 7/142003 <br />