My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0010975_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MIDDLE
>
13400
>
2600 - Land Use Program
>
UP-96-0002
>
SU0010975_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2020 5:09:51 PM
Creation date
9/6/2019 10:11:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0010975
PE
2656
FACILITY_NAME
UP-96-0002
STREET_NUMBER
13400
Direction
W
STREET_NAME
MIDDLE
STREET_TYPE
RD
City
TRACY
Zip
95304-
APN
21204002
ENTERED_DATE
7/15/2016 12:00:00 AM
SITE_LOCATION
13400 W MIDDLE RD
RECEIVED_DATE
7/15/2016 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\M\MIDDLE\13400\UP-960002\SU0010975\SS NL STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1 <br /> SOIL PROFILE CHARACTERISTICS AND <br /> ANALYTICAL TEST RESULTS <br /> SAMPLE LOCATION SAND,SILT AND SOIL SOILNITROGEN pH AND <br /> AND SAMPLE DEPTH CLAY CLASSIFICATION CONTENT CATION EXCHANGE <br /> PERCENTAGES CAPACITY <br /> DISPOSAL FIELD AREA 14% 30% 56% Clay 5ppmNO,-N 7.3 24.3meq/100g <br /> 04 FT IN DEPTH <br /> C. PERCOLATION AND INFILTRATION TEST RESULTS <br /> SSS§ 6.2. To assess the permeability and the infiltration capabilities of the proposed mound system <br /> area,two percolation tests were completed in this area as depicted in the Site Plan. As referenced, <br /> the test depths were 24 and 36 inches below existing grade, giving a comparatively detailed <br /> observation of subsurface permeability at these two strata. Only the 36-inch test depth is recognized <br /> as "official'by EHD. The 24-inch test depth represents infiltration properties of the soil near the <br /> surface._ <br /> SSS§ 6.3. On August 8, 2016,the two perc test borings were drilled. The sidewalls of each boring <br /> were scored with a pry-bar to open potentially smeared sidewalls. Two inches of pea gravel was <br /> placed at the bottom and three-inch perforated PVC pipe was inserted in each test boring. Each <br /> boring was then pre-saturated with water at 3x each bore hole volume at 0900 hrs; 24 hrs before the <br /> start of testing. This greatly exceeds EHD pre-saturation standards. <br /> SSS§ 6.4,16.5. On August 9, 2016, percolation testing commenced. No standing water was <br /> observed after the 24-hr soak period in either of the two test borings. Consequently, EHD Perc Test <br /> Procedure#2 was conducted in which testing was done over a four-hour period to induce maximum <br /> soil saturation. The test results indicate comparatively rapid perc rates considering the soil type at <br /> 10.0 minutes per inch(min/in) and 17.8 min/in as noted below. <br /> A summary of the perc test results with corresponding application rates in gallons of effluent <br /> accepted per square foot of soil per day are found in Table 2: <br /> TABLE 2 <br /> PERCOLATION TEST RESULTS FOR THE DISPOSAL AREA MOUND SYSTEM <br /> WITH CORRESPONDING APPLICATION RATES <br /> IN GALLONS J FTS/DAY <br /> 24 INCH DEEP PERC TEST BORING 10.0 min/inch / 0.800 gallons/ft'/day <br /> PERCOLATION RATE/APPLICATION RATE , <br /> 36 INCH DEEP PERC TEST BORING 17.8 min/inch / 0.686 gallons/ft2/day <br /> PERCOLATION RATE/APPLICATION RATE ' <br /> Application Rates adapted from Water Quality Control Policy for Siting,Design,Operation,and Maintenance of Onsite Wastewater Treatment Systems. <br /> 4 <br /> Chesney Consulting <br />
The URL can be used to link to this page
Your browser does not support the video tag.