Laserfiche WebLink
00-09-'05 16,03 FROM-DILJ & MURPHY 1-209-334-0723 T-843 P03/04 U-113 <br /> 3.7 Description of Proposed or Expected Maximum(including second unit dwellings)septic <br /> tank usage on site. The four parcels will likely have only primary residences, no second unit <br /> dwellings are planned. Thus only one septic system per parcel is anticipated at this time, per <br /> County ordinances, each parcel on this map is entitled to one primary residence and one second j <br /> unit dwelling. Due to the current number of septic systems and potential for new systems,this <br /> property could ultimately have 10 septic systems. <br /> I <br /> 4.0 GROUNDWATER INFORMATION SECTION: <br /> /`/4.1 Description of the depth and gradient of groundwater in the general area. The depth to <br /> E ground water in this area is approximately 130 feet according to the map of"Lines of Equal <br /> Depth to Groundwater" published Spring, 1999,by the San Joaquin County Flood Control and <br /> /Water Conservation District. The gradient descends from east to west. <br /> 4.2 DescriptioWDiscussion of any existing and/or potential groundwater contamination <br /> issues-in the general location of the site., The concerns for groundwater contamination in this <br /> area is deemed low due to the depths involved. Insecticides,pesticides, and fertilizers typically <br /> do not impact groundwater at these depths, however, as with any agricultural area,there is <br /> always potential for contamination due to chemicals used iu the farming operation. .Nitrate <br /> ...� _ <br /> levels were surprisingly low considering the past land use, but the dsbromochloropropane <br /> (DBCP)levels measured near.the maximum safe zone...A filter for,any future or.existing <br /> wells is recommended due to these finclings., <br /> ... - -xc ..L <br /> 4.3 Description of location,type and construction of well and location where water <br /> sample(s) were obtained: Water samples were taken from a spigot at the house located at <br /> 23490 N. Jack Tone Road on May 12, 2005 by Louie Mendez of Dillon&Murphy. The water <br /> samples were obtained at this location due to the fact that the home lies within the boundaries of <br /> this project. <br /> 4.4 Description of constituents being tested for in the water sample: The water samples <br /> are being tested for nitrates and DBCP. The results for dibroznochloropropane(DBCP)were <br /> 0.225 ug/L and the results for nitrates were 11.6 mg/L. <br /> 4.5 Description of how sample was obtained,handled,stored,and transported to the lab: <br /> The water samples were obtained from the spigot at the house located 23490 N. Jack Tone Road. <br /> The samples were taken by Louie Mendez of Dillon&Murphy, and driven directly to Precision <br /> Enviro-Tech. The samples were taken and handled in accordance with Precision Enviro-Tech <br /> requirements. The results from the test can be found in the Appendix. <br /> 4.6 Complete Chain of Custody document, including printed nod signed name of third <br /> party sampler,condition of sample and date and time the sample was submitted to the <br /> lab. For Laboratory samplers, complete laboratory report to include the above noted <br /> information: The complete chain of custody document is located in the Appendix, <br /> i <br /> 2 <br /> rV(!d7l1VCn;1 Ra..n.r <br />