Laserfiche WebLink
Percolation Test <br /> f A percolation test involving shallow and deep holes was conducted on each parcel of <br /> the Site; the soil borings discussed above were used for the percolation test holes <br /> (Plate 2). Percolation test procedures conformed to San Joaquin County Environmental (&.J <br /> Health Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the borings were advanced by hand auger and the soils logged, the test holes <br /> were completed for the percolation tests. Approximately one inch of pea gravel was <br /> ;placed in the bottom of each open soil boring, followed by a 1.5-inch diameter PVC pipe <br /> with perforations on the bottom. Pea gravel was then used to backfill a few inches of <br /> the annular space. <br /> !rave Oak presaturated the percolation test holes approximately 24 hours prior to the <br /> percolation test. The holes were filled with water to a height of 12 inches above the <br /> bottom of the boring for the presaturation. On the day of testing, the deep holes were <br /> found to be intact and dry, while standing water was encountered in the shallow holes. <br /> Percolation Test Procedure <br /> :Live Oak conducted the percolation tests for the borings on July 28, 2010. Due to initial <br /> percolation rates observed, four-hour tests were selected. Water level measurements <br /> were taken every half-hour during this four-hour period. Michael Escotto, Senior <br /> Registered Environmental Health Specialist at the San Joaquin County Environmental <br /> Health Department, observed the last half-hour of the tests. <br /> An electronic well sounder with a depth accuracy of 1/10& foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the hole was refilled with water <br /> to a level of six inches above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test forms are included in Appendix 3 of this report. The <br /> forms were signed by Mr. Escotto and indicate percolation rates for the holes based on <br /> the final water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is less than or equal to 60 minutes per inch (min/in) drop. A deep <br /> percolation test hole has a depth greater than 3.5 up to 25 feet; a 'satisfactory <br /> percolation rate for a deep test is 30 mintin or less. For the Site to utilize a standard <br /> LOGE1017 Page g <br />