EIVIKo�INET�it. <br /> Analytical Chemists <br /> ..�.r fglinc.corll # 'r <br /> May l 1,2011 Lab ID : STK1133373 <br /> Live Oak Geo Environmental Customer : 3-16608 <br /> Quality Control - Organic <br /> onstitnent Method Date/LD Type Units Conc. QC Data DQO Nate <br /> rganic <br /> 13-Dibromopropane 504 05/0212011:204693 Blank u911- 05868 985% 70-130 <br /> LCS ug/L 05868 104% 70-130 <br /> MS ug/L. 05868 103% 70-130 <br /> (STKI 133379-001) MSD ug/L 0.5868 109% 70-130 <br /> MSRPD ug/L 0S868 5.1% 40 <br /> Blank ug/L- 0_5W 99.6% 70-134 <br /> LCS ug/L 0.5868 99.5% 70-130 <br /> ff MS ug/L 0.5868 102% 70-130 <br /> (STK1133506-001) MSD ug/L 05868 103% 70-130 <br /> MSRPD u 05868 0.9% c30 <br /> BCP 504 0510212011:204693 Blank ug/L ND a0.01 <br /> lCS ug/L 0.2950 104% 70-130 <br /> MS ug/L 0.2950 106% 70-130 <br /> (STKI.133379-001) MSD ug/L 0.2950 112% 70-130 <br /> MSRPD ug/L 11 05868 53% 530 <br /> Blank ug/L ND <0.01 <br /> LCS ug/L, 0.2950 10.1 % 70-130 <br /> MS ug/L 0.2950 106% 70-130 <br /> (STK1133506-001) MSD ug/L 0.2950 110% 70-130 <br /> MSRPD I ug/L 1 0-5868 3.5% 1 530 <br /> 13DBP 504.1 05/02/2011:206296 CCV ug/L 7.481 102% 70-130 <br /> CCV ug/L 7.481 107% 70-130 <br /> CCV ug/L 9.975 105% 70-130 <br /> CCV u /L 9.975 107% 70-130 <br /> BCP 504.1 05/021201.1:206296 CCV u9/L 2.006 107% 70-130 <br /> CCV ug/L. 2.006 111 % 70430 <br /> CCV ug/L 5.015 108% 70-130 <br /> CCV ug/L 5-015 1 113% 1 70-130 <br /> Definition <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyted.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> DQQ :Data Uality oNective-This is the criteria a ainst which the uali control data is compared, <br /> Page 6 of 7 <br /> Corporate Offices&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory Field Office <br /> 853 Corporation Street 2500 Stagecoach Road 563 E.Lindo Avenue 3442 Empresa Drive,Suite D Visalia,California <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 San Luis Obis CA 93401 <br /> TEL:8051392-2000 TFL:2091942-0182 �, TEL:5591734-9473 <br /> TEL:53013435818 TEL:8051753-2940 Mobile;559f737-2399 <br /> FAX:8051525-4172 FAX:2091942-0423 FAX:5301343-3807 FAX:806/525-4172 FAX:5591734-8435 <br /> CA NELAP Certification No.011 f OCA CA FLAP Certification No.1563 CA ELAP Certification No,2670 CA FLAP Certification No.2775 <br />