My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011909
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LARCH
>
11075
>
2600 - Land Use Program
>
PA-1800185
>
SU0011909
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:31 AM
Creation date
9/6/2019 10:47:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011909
PE
2631
FACILITY_NAME
PA-1800185
STREET_NUMBER
11075
Direction
W
STREET_NAME
LARCH
STREET_TYPE
RD
City
TRACY
Zip
95304-
APN
21217002
ENTERED_DATE
8/22/2018 12:00:00 AM
SITE_LOCATION
11075 W LARCH RD
RECEIVED_DATE
8/20/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LARCH\11075\PA-1800185\SU0011909\APPL.PDF \MIGRATIONS\L\LARCH\11075\PA-1800185\SU0011909\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQ U I N Environmental Health Department <br /> COUNTY— Linda Turkatte, REHS, Director <br /> '• �`,Fo�,j$-' Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, REHS, RDI <br /> Michael Kith, REHS <br /> Willy Ng,REHS <br /> September 2, 2018 Muniappa Naidu, REHS <br /> To: San Joaquin County Community Develo nt Department �p <br /> Attention: Giuseppe Sanfilippo �( r r� <br /> From: Michael Kith; (209) 468-3444 fi �W <br /> REHS Program Coordinator <br /> RE: PA-1800185 (SA), S00011909 <br /> 11075 W. Larch Road, Tracy <br /> The San Joaquin County Environmental Health Department (EHD) cannot complete an evaluation of <br /> the referred application noted above based on the lack of information provided on the application and <br /> plot plan. Until and unless adequate information is provided to enable an appropriate evaluation, the <br /> EHD cannot support the approval of the site approval project, as proposed. <br /> The current identified issues that need to be resolved with this project are detailed below. <br /> Application –the application does not provide sufficient scope of development and contains <br /> conflicting information. <br /> 1. The application does not provide sufficient information to determine the requirements for water and <br /> sewage. The full scope of activities to be conducted in the religious assembly/multipurpose building <br /> needs to be described in detail, including the activities and building improvements related to the <br /> storage and distribution of food. Any current or future intent to install a kitchen or similar <br /> improvement must be identified at this time, as it will impact the requirements for the provision of <br /> sewage disposal. <br /> 2. The application indicates that the existing potable water is served by the City of Tracy, but also <br /> indicates that the existing potable water is served by an existing private well. Additional information <br /> needs to be submitted to describe in detail how the project will be provided potable water. Please <br /> also see the comments concerning the provision of water below. <br /> 3. The application indicates proposed public sewage disposal, but provides no service provider. The <br /> application also indicates a new onsite wastewater treatment system (OWTS) is proposed. <br /> Additional information on the provision of sewage disposal needs to be submitted. Please also see <br /> the comments concerning the provision of sewage disposal below. <br /> Plot Plan –the plot plan provides inaccurate and insufficient information. <br /> 1. The OWTS serving the existing residence is not accurately represented on the plot plan. The scope <br /> of the OWTS repair installed in 2002 (permit SR0028824) needs to be accurately represented on <br /> the plot plan and drawn to scale. The 100% OWTS future repair area needs to be accurately <br /> represented on the plot plan and drawn to scale. <br /> 2. The 2002 OWTS repair permit (SR0028824) did not show the onsite well at the location shown on <br /> the current project plot plan, but showed it located in north west corner of lot. The current plot plan <br /> shows the well located close to the area where the 2002 OWTS repair is located. This OWTS may <br /> be located within the required setback of the well. These issues need to be investigated further. All <br /> items on the parcel must be represented and drawn to scale on the plot plan. <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.