My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004313_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINNE
>
10304
>
2600 - Land Use Program
>
PA-0200298
>
SU0004313_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2020 11:53:49 AM
Creation date
9/6/2019 10:55:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0004313
PE
2632
FACILITY_NAME
PA-0200298
STREET_NUMBER
10304
Direction
W
STREET_NAME
LINNE
STREET_TYPE
RD
City
TRACY
ENTERED_DATE
5/17/2004 12:00:00 AM
SITE_LOCATION
10304 W LINNE RD
RECEIVED_DATE
7/11/2002 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\L\LINNE\10304\PA0200298\SU0004313\SOIL SUITABILITY STUDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
January 7;2003 <br /> Job-Number:LG02-026 , <br /> Page 5 <br /> �•= The percolation test ca.sing set in each boring was an open ended 2-inch PVC.pipe with holes <br /> drilled on the bottom., Two inches of "pea gravel"was placed in the bottom.of the percolation <br /> test holes; the casing was installed;and several feet of" ea avec"was backfilled in the annular <br /> space. The presaturation was performed on December 3, 2002'. <br /> IF A 4-hour percolation test-was conducted on.December 4,2002 in accordance with"the <br /> requirements of Sari Joaquin County Envirom- ental Health Division The last '/z hour of the test <br /> was 'observed by a representative of that office. The result of the shallow (3-foot deep). <br /> percolation test indicated a percolation rate of 14.7 minutes per inch. The result of the deep <br /> ' pereolatioD test achieved a satisfactory percolation rate of less than 3.8 minutes per inch. <br /> 5.0 SUITABILITY OF EXISTING,SEPTIC SYSTEM <br /> As describedp reviouslY,the existing septic system,is composed of two tanks and one disposal <br /> area connected by tight lines. According to a septic system permit dated l l/18/92, the sewage <br /> disposal area is two (2) filter beds, 6.5 feet-by 80 feet each. The filter bed area was designed for <br /> 10 to 15 employees. <br /> It is estimated that for the proposed expansion„ a maximum of 37 employees and 5 customers <br /> will be on site during atypical 5 day work week. The caretaker residence is a 2 bedroom mobile <br /> home occupied by 1 person."Fifteen(15) gallons per day per person was assigned for the 37 <br /> einployees for an industrial building category(no cafeteria)according to the San Joaquin County <br /> Sewage Stan&ids. An estimate of 5 gallons per day per person was made for customers. <br /> According to the text book titled Small and Decentralized Wastewater.Management Systems by <br /> Crites and Tchobanoglous 6, 70 gallons per day per person was assigned to the mobile home <br /> occupant. Table 2 presents an estimate of average daily flow for sewage,at the proposed facility. <br /> 6. .Crites,R.and Tchobanoglous.G_, 199&, Small and Decentralized Wastewater Management Systems: <br /> K McGraw-Hi11'Publishing Company,Boston. <br /> z <br /> o � <br />
The URL can be used to link to this page
Your browser does not support the video tag.