Laserfiche WebLink
ENVIRONMENTAL AGRJCULTURAL <br /> September 16,2015 Lab ID : STK1539475 <br /> Live Oak Geo Environmental Customer : 3-16608 <br /> Quality Control- Organic <br /> Constituent Method Date/1D Type Units Cone. QC Data DQO Note <br /> Organic <br /> 12-Dibromoetbane(EDB) 504 08/28/15:210089SBL Blank ug/L ND <0.02 <br /> LCs ug/L 02666 103% 70-130 <br /> LCS ug/L 02665 106% 70-130 <br /> MS ug/L 0.2508 121% 70-130 <br /> (STK1539403-001) MSD ug/L 0.2496 116% 70-130 <br /> MSRPD ug/L 05857 42% 530 <br /> MDL u 0.04142 62.5% 60-140 <br /> 1,3-Dibromopropane 504 08/28115:210089SBL Blank ug/L 0.6242 83.6% 70-130 <br /> LCS ug(L 0.6258 93.4% 70-130 <br /> LES ug/L 0.6256 86A% 70-130 <br /> MS ug/L 05887 103% 70-130 <br /> (STK1539403-001) MSD ug/L 05857 99.9% 70-130 <br /> MSRPD ug/L 05857 3.7% 530 <br /> MDL ug/L 0.6122 105% 70-130 <br /> BCP 504 08/28/15:210089SBL Blank ug/L PID <0D1 <br /> LCS ug/L 02666 96.9% 70-130 <br /> LCS ug/L 0.2665 99.1% 70-130 <br /> MS ug/L 0.2508 114% 70-130 <br /> (STK1539403-001) MSD ug/L 02496 114% 70-130 <br /> MSRPD ug/L 05857 0.6% <30 <br /> MDL ug/L 0.04142 108% 60-140 <br /> l3DBP 504.1 0829/15:212732SBL CCV ug/L 9.975 101% 70-130 <br /> CCV ug/L 2.494 126% 70-130 <br /> CCV ugfL 9.975 103% 70-130 <br /> BCP 504.1 0829/15:212732SBL CCV ug/L 5.000 105% 70-130 <br /> CCV ug/L 2.000 87.5% 70-130 <br /> CCV u L 5.000 106% 70-130 <br /> DB 504.1 0829/15:212732SBL CCV ug/L 5.000 111% 70-130 <br /> CCV ug/L 2.000 92.0% 70-130 <br /> CCV ug/L 5.000 110% 70-130 <br /> Definition <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pain-A random sample duplicate is spiked with a known amount of analyted.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD .MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysts. <br /> ND :Non-detect-Result was below the DQO listed fm the analyte. <br /> DOD Data Quality Objective-This is the criteria against which the qualit.Lcontral data is compared. <br /> Page 6 of 7 <br /> Corporate Offices&Laboratory ORI. orINR <br /> &Laboratory 011s.&Laboratory Office&Laboratory Office&Laboratory <br /> 853 Corporation Street 2500 Stagecoach Road 563 E.Lando Avenue 3442 Empresa Drive,Suite D 9415 W.Goshen Avenue <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 Sen Luis Obispo,CA 93401 Visalia,CA 93291 <br /> TEL:(1](15)392-2000 TEL;(209)942-0182 TEL:(530)343-5818 TEL:(805)783-294C TEL:(Mg)734-9473 <br /> Env FAX:(805)5254172/Ag FAX:(805)392-2063 FAX:(209)942-0423 FAX:(530)313-3807 FAX:(805)783-2912 FAX:(559)7348435 <br /> CA ELAP certification No.1573 CA ELAP Certification No.1563 CA ELAP Certification No,2670 CA El-AP Certification No,2775 CA ELAP Certification No.2810 <br />