i
<br /> ' cooler,storage rooms,structures and equipment)—Cie� rfaces before treatment Sweep 6) Systems must use a Ing pump,such as a positive displacement injection pump
<br /> and remove all plant debris,and use power sprayer to v,__ ell surfaces to remove loose dirt. (e.g., diaphragm pu, effectively designed and constructed of materials that are
<br /> Use a dilution of 1:600 of SanlDate 12-0 for all non-porous surfaces that have been pre-cleaned compatible with pesticiaes and capable of being filled with a system Interlock.
<br /> with water.Apply solution with mop,sponge,power sprayer or fogger to thoroughly wet all 7) Do not apply when wind speed favors drift beyond the area intended for treatment.
<br /> surfaces.Cutting tools may be soaked to ensure complete coverage.Allow surfaces to stay wet
<br /> with solution for a minimum of(5)minutes.Heavy growths of algae and fungi may have to be Specfflc Requirements for Flood Chemigation-
<br /> Scrubbed off following application.Repeat treatment as required to maintain control. 1) Systems using a giavity flow pesticide dispensing system must meter the pesticide Into the
<br /> water at the head of the field and downstream of a hydraulic discontinuity such as a drop
<br /> TREATMENT OF GREENHOUSE EVAPORATIVE COOLERS:Treat contaminated surfaces with a structure or weir box to decrease potential for water source contamination from backflow
<br /> dilution of 1:600 of SanlDate 12.0.Allow surfaces to stay wet with solution for a minimum of If water flow stops.
<br /> (5)minutes.For maintenance,treat cooler water once a week with a dilution of 1:2,000 of 2) The systems utilizing a pressurized water and pesticide Injection system must meet the fol-
<br /> SaniDate 12.0 for every gallon of cooling water. lowing requirements.
<br /> a. The system must contain a functional check valve,vacuum relief valve an low-pres-
<br /> sTREATMENT OF GREENHOUSE IRRIGATION SYSTEMS:(such as flooded floors,flooded benches, sure drain appropriately located an the irrigation pipeline to prevent water ource
<br /> recycled water systems,drip trickle,capillary matt,sprinkler systems,humidification and misting contamination from backflow.
<br /> systems)For shock treatment of irrigation lines,use a dilution rate of 1:5,000.Allow solution to b. The pesticide injection pipeline must contain a functional, automatic, quick-closing
<br /> remain In lines for 1243 hours.Flush by opening flush valves or laterals to avoid clogging emit- check valve to prevent the flow of fluid back toward the Injection pump.
<br /> ters.For maintenance,treat clean water with a dilution of 1:50,000 to 1:100,000 of SaniDate c. The pesticide infection pipeline must also contain a functional normally dated solenoid-
<br /> 12.0 as needed. operatedvah+e located on the Intake side ofthe injection pump and connected to the system
<br /> in%Tkx c to prevent-fluid from being withdrawn from the supply tank when the irrigation
<br /> CHEMIGATION: system Is either automatically or manually shut dawn.
<br /> I d. The system must contain functional interlocking controls to automatically shut off the
<br /> General Requirements-
<br /> Ipesticide injection pump when the waterpump motor stops.
<br /> i 1) Apply th€s product only through a drip system or sprinkler system,Including flood,and
<br /> e• The Irrigation line or water pump must include a functional pressure switch which
<br /> drip(trickle)Irrigation systems.
<br /> 2) Crop injury,lack of effectiveness,or illegal pesticide residues in the crop can result from will stop the water pump motor when the water pressure decreases to the point
<br /> non-uniform distribution of treated water. where pesticide distribution is adversely affected.
<br /> 3) If you have questions about calibration,you should contact State Extension Service spe- f. Systems must use a metering pump,such as a positive displacement injection pump
<br /> cialists,equipment manufacturers or other experts. (e.g.,diaphragm pump)effectively designed and constructed of materials that are com-
<br /> 4) Do not connect an irrigation system(including greenhouse systems)used for pesticide patible with pesticides and capable of being filled with a system interlock.
<br /> application to at public water system unless the pesticide label-prescribed safety devices
<br /> for public water systems are In place. Specific Requirements for Drip(Trickle)chemigation-
<br /> 5) A person knowledgeable of the chemigation system and responsible for Its operation, 1) The system must contain a functional check valve,vacuum relief valve and low-pressure
<br /> or under the supervision of the responsible person,shall shut the system down and drain appropriately located on the irrigation pipeline to prevent water source contam-
<br /> make necessary adjustments should the need arise. !nation from backflow.
<br /> 6) Posting of areas to he chemlgated is required when 1)any part of a treated area is vdWn' 2) The pesticide injection pipeline must contain a functional, automatic,quick-closing check
<br /> 300 feet of sensitive areas such as residential areas,labor camps,businesses,day care cen- valve to prevent the flow of fluid back toward the injection pump.
<br /> ters,hospitals,in-patient clinics,nursing homes or any public areas such as schools,parks, 3) The pesticide injection pipeline must also contain a functional,normally closed,solenoid-
<br /> playgraunds,or other public facilities not including public roads,or 2)when the chemiget- operated valve located on the intake side of the injection pump and connected to the sys-
<br /> ed area is open to the public such as golf courses or retail greenhouses. tem interlock to prevent fluid from being withdrawn from the supply tank when the Irriga-
<br /> 7) Posting must conform to the following requirements.Treated areas shall be posted with tion system is either automatically or manually shut down.
<br /> signs at all usual points of entry and along likely routes of approach from the listed sen- 4) The system must contain functional interlocking controls to automatically shut off the
<br /> sitive areas.When there are no usual points of entry,signs must be posted in the comers pesticide injection pump when the water pump motor stops.
<br /> of the treated areas and in any other location affording maximum visibility to sensitive 5) The irrigation line or water pump must include a functional pressure switch which will
<br /> areas.The printed side of the sign should face away from the treated area towards the stop the water pump motor when the water pressure decreases to the point where
<br /> sensitive area.The signs shall be printed in English. Signs must be posted prior to appll- pesticide distribution is adversely affected.
<br /> cation and must remain posted until foliage has dried and soil surface water has'disap- 6) Systems must use a metering pump, such as a positive displacement injection pump structed of materials that are
<br /> i peered. Signs may remain in place IndeflnRely as long as they are composed of materials (e.g., diaphragm pump) effectively designed and con
<br /> compatible with pesticides and capable of being filled with a system interlock.
<br /> to prevent deterioration and maintain legibility for the duration of the posting period.
<br /> 8) All words shall consist of letters at least 2.5 inches tall,and all letters and the symbol shall be A lication Instructions-
<br /> a color which sharply contrasts with their immediate background.At the top of the sign shall 1)p Remove scale,pesticide residues,and other foreign matter from the chemical supply tank
<br /> be the words KEEP OUT,followed by an octagonal stop sign symbol at least B Inches in clam• and entire Injector system.Flush with clean water.Failure to Provide a clean tank,void of
<br /> etercarrtaining the word STOP. Below the symbol shall be the words PESTICIDES 1N fRR1GA- scale or residues may cause product to lose effectiveness or strength.
<br /> TION WATER. 2) Determine the treatment rates as indicated in the directions foruse and make proper dilutions.
<br /> Specific Requirements for chemigation Systems Connected to Public Water System- 3) Prepare a solution in the chemical tank by filling the tank with the required water and
<br /> 1) Publitwater system means a system forthe provision to the public of piped water for human then adding product as required.The product will immediately go Into suspension
<br /> consumption if such system has at least 15 service connections or regularly serves an average without any required agitation.
<br /> i of at least 25 Individuals daily at least 60 days out of the year. 4) oo not apply San€Date 12.0 in conjunction with any other pesticides or fertilizers;this has the
<br /> 2) ChemEgation systems connected to public water systems must contain a functional, potential to cause reduced performance of the product. Avoid application in this manner.
<br /> reduced-pressure zone,backflow preventer(RP2)or the functional equivalent In the
<br /> water supply line upstream from the point of pesticide Introduction.As an option to STORAGE&DISPOSAL
<br /> the RPZ,the water from the public water system should be discharged into a reservoir
<br /> tank prior to pesticide introduction.There shall be a complete physical break(air gap) DO NOT CONTAMINATE WATER,FOOD OR FEED SY STORAGE OR DISPOSAL
<br /> between the outlet end of the fill pipe and the top or overflow rim of the reservoir
<br /> tank of at least twice the inside diameter of the fill pipe. STORAGE: Store in original vented container in a dry location away from heat and
<br /> 3) The pesticide Injection pipeline must contain a functional, automatic, quick-closing out of direct sunlight, in case of fire Involving product,use water. in case of large
<br /> check valve to prevent the flow of fluid back toward the injection pump. quantities of spilled material,dike with sand or earth. Dilute with large quantities
<br /> 4) The pesticide Injection pipeline must contain a functional,normally closed,solenoid- of water.
<br /> operated valve located on the Intake side of the Injection pump and connected to the
<br /> system interlock to prevent fluid from being withdrawn from the supply tank when the PESTICIDE DISPOSAL:Pesticide wastes are acutely hazardous,Improper disposal of
<br /> irrigation system is elther automatically or manually shut down. excess pesticide spray mixture or rinsate is a violation of Federal law. Do not dis
<br /> 5) The"am must contain functional interlocking controls to automatically shut off the charge effluent containing this product Into lakes,streams,ponds,estuaries,or pub-
<br /> pesticide injection pump when the water pump motor stops,or in cases where there Is lic waters unless the components of this product are specifically'identified and
<br /> no water pump,when the water pressure decreases to the point where pesticide dis- addressed In a NPDES permit.Do not discharge effluent containing this product into
<br /> tribution Is adversely affected. sewer systems without previously notifying the sewage plant authority.'For addition-
<br /> 6) Systems must use a metering pump,such as a positive displacement Injection pump al Information,refer to the product Material Safety Data Sheet.
<br /> (e.g., diaphragm pump) effectively designed and constructed of materials that are
<br /> compatible with pesticides and capable of being fitted with a system interlock. CONTAINER DISPOSAL:(Plastic Containers 30,and 55 gallon drums):Triple rinse(or equly-
<br /> 7) Db not apply when wind speed favors drift beyond the area intended for treatment alent)then offer for recycling or reconditioning or puncture and dispose of in a sanitary
<br /> landfill or incineration or,if allowed by state and local authorities,by burning.If burned,
<br /> Specific Requirements for Sprinkler Chemigetlon-
<br /> stay out of smoke.(For 275 gallon totes)Triple rinse(or equivalent
<br /> 1) The system must contain a functional check valve,vacuum relief valve and low-pressure ),?hen dispose of in a
<br /> drain appropriately located on the irrigation pipeline to prevent water source contam-
<br /> ination from backflow.
<br /> 2) The pesticide Injection pipeline must contain a functional, automatic, quick-closing w
<br /> check valve to prevent the flow of fluid back toward the Injection pump. BiSafe Systems
<br /> 3) The pesticide Injection pipeline must also contain a functional,normally dosed,solenoid- i-L.G
<br /> operated valve located on the Intake side of the injection pump and connected
<br /> o tthe.
<br /> sys-
<br /> tank n
<br /> tem Interlock to prevent fluid from being withdrawn from the supply 9 - For additional Information on SanlDate 12.0 MieroBlocide
<br /> tion system is either automatically or manually shut down• call us toil-free at 1.888.273.3088.
<br /> 4) The system must contain functional Interlocking controls to autom_atically shut off the
<br /> pesticide injection pump when the water pump motor stops.
<br /> 5} The irrigation line or water pump must include a functional pressure switch which will 02009 Copyright 81oSa a Systems LLC.05aniDate 12.0 Mlcrobiocide is a registered
<br /> stop the water pump motor when the water pressure decreases to the point where trademark of BIoSafe Systems 09V4A120Z08V9read 17 6falfow label directions.
<br /> pesticide distribution is adversely affected.
<br />
|