SU0004714
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
2600 - Land Use Program
>
UP-98-22
>
SU0004714
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 1:05:24 PM
Creation date
9/6/2019 11:06:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0004714
PE
2627
FACILITY_NAME
UP-98-22
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
APN
19119006
ENTERED_DATE
11/18/2004 12:00:00 AM
SITE_LOCATION
500 E LOUISE AVE
RECEIVED_DATE
1/3/1989 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\APPL.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\CDD OK.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\EH COND.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\EH PERM.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
695
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
25 <br /> .r Vlor — <br /> To compute the estimated settlements shown on Plates 42 through 44, we used <br /> compression parameters that are considered typical of a compacted structural sand <br /> fill to represent the subsurface in the zone of improved materials. For total <br /> removal and replacement with compacted structural fill, the thickness of improved <br /> or replaced materials (shown on Plate 42 through 44) will be 16 ft. For the <br /> partial removal and recompaction options, the thickness of improved or replaced <br /> materials equates to the depth of removal below the existing ground surface. For <br /> DDC treatment, we would anticipate settlements to be less than the estimated <br /> settlements for an 8 ft thickness of improved soils. We anticipate post DDC <br /> settlement to be equivalent to a 12 to 16 ft depth of improvement. <br /> Because the soils are predominantly granular materials, significant portions <br /> of the settlements will occur relatively rapidly as, and shortly after, the loads <br /> are applied. We suggest that one half of the values shown on Plates 42 through <br /> 44 be considered as immediate settlements. <br /> FOUNDATION DESIGN RECOMMENDATIONS <br /> Turbine and Boiler Mat Foundations <br /> Location, Size and Loads. The boiler and turbine are to be located in the - <br /> south central part of the "plant" area. Foundation mat sizes and anticipated <br /> loads, as supplied by PSE, are given in the following table: <br /> Foundation Estimated Estimated Gross Static <br /> Dimensions (ft) Load (kips)' Bearing Pressure (psf) <br /> Turbine 81 x 15 1,140 940 <br /> Boiler 86 x 22 2,130 1,130 <br /> •Including 3.5- to 4-ft-thick foundation mat. , <br /> Recommended Foundation Type and Depth. Extensive glass deposits are present <br /> at the location of the boiler and turbine. Thus, we recommend that these two <br /> pieces of equipment be founded on piles driven into the sands that are present at <br /> about El -20 to -25 ft. Allowing for tip penetration into the sand, the planned <br /> grade raise at the site, and embedment into the pile caps, the pile order lengths <br /> are anticipated to be about, or slightly greater than, 40 ft. <br /> 1144A/CC-25McClelland <br />