My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004714
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
2600 - Land Use Program
>
UP-98-22
>
SU0004714
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 1:05:24 PM
Creation date
9/6/2019 11:06:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0004714
PE
2627
FACILITY_NAME
UP-98-22
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
APN
19119006
ENTERED_DATE
11/18/2004 12:00:00 AM
SITE_LOCATION
500 E LOUISE AVE
RECEIVED_DATE
1/3/1989 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\APPL.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\CDD OK.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\EH COND.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\EH PERM.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
695
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMERICAN NATIONAL STANDARD K61.1-1981 <br /> tube, fixed tube, and slip tube devices, shall be with Department of D-ansportation Specifica. <br /> designed so that the maximum opening of the tions. All Basic Rules of Section 2 apply to this <br /> bleed valve is not larger than No: 54 drill size section unless otherwise noted <br /> unless provided with an excess now valve. (This <br /> requirement does not apply to farm vehicles used 3.1 Design Pressure and Construction <br /> for the application of ammonia as covered in <br /> Section 8.) of Containers <br /> 2.14.4 Gaging devices shall have a desi n 3.1.1 The minimum design pressure for non- <br /> pressure equal to or greater than the design refrigerated aboveground containers shall be <br /> pressure of the container on which they are 250 psig(1720 kPa). [See 2.2.1.1) <br /> installed. NOTE: U-68 and U-69 ASM E Code containers with a design <br /> pressure of 200 psig are acceptable if recertified to 250 psig <br /> 2.14.5 Fixed liquid level gages shall be so and equipped with pressure relief valves set at 250 psig as <br /> designed that the maximum volume of the permitted in 2.9.2. <br /> container filled by liquid shall not exceed 85 0 of <br /> its water capacity. The coupling into which the 3.2 Container Valves and Accessories,Filling <br /> fixed liquid level gage is threaded must be placed and Discharge Connections <br /> at the 85% level of the container. If located 3.2.1 Each filling connection shall be provided <br /> elsewhere, the dip tube of this gage must be with combination back-pressure check valve and <br /> installed in such a manner that it cannot be excess flow valve;one double or two single back- <br /> readily removed. pressure check valves;or a positive shut-off valve <br /> NOTE: This does not apply to refrigerated storage. in conjunction with either an internal back- <br /> 2.14.6 Gage glasses of thecolumnart pressure check valve or an internal excess flow <br /> type valve. <br /> be restricted to stationary storage installations. <br /> They shall be equipped with shut-off valves 3.2.2 All vapor and liquid connections,except <br /> having metallic handwheels, with excess-flow pressure relief valves and those specifically <br /> valves, and with extra heavy glass adequately exempt in Sections 2.6.4 and 2.6.5 shall be <br /> protected with a metal housing appplied by the equipped with approved excess flow valves;or in <br /> gage manufacturer. They shall be shielded lieu thereof,may be fitted with approved quick- <br /> against the direct rays of the sun. closing internal valves which, except during <br /> operating periods, shall remain closed. <br /> 2.15 Painting of Containers 3.2.3 Each storage container shall be provided <br /> 2.15.1 Aboveground uninsulated containers with a pressure gage graduated from 0 to 400 <br /> should have a reflective surface maintained in psig(0-275kPa). Gages shall be designated for <br /> good condition. White is recommended for use in ammonia service. <br /> painted surfaces,but other light reflecting colors 3.2.4 All containers shall be equipped with an <br /> are acceptable. approved vapor return valve. <br /> 2.16 Electrical Equipment and Wiring 3.2.5 All containers shall be equipped with a <br /> fixed maximum liquid level gage. <br /> 2.16.1 Electrical equipment and wiring for <br /> use in ammonia installations shall be general 3.3 Pressure Relief Devices <br /> purpose or weather resistant as appropriate. 3.3.1 Every container shall be provided with <br /> 2.16.2 Where concentrations of ammonia in one or more pressure relief valves of spring- <br /> air in excess of 16% by volume are likely to be loaded or equivalent type and shall comply with <br /> encountered, electrical equipment and wiring the following: <br /> shall be of a type specified by and be installed in (a) The discharge from pressure relief valves <br /> accordance with National Electrical Code,NFPA shall be directed away from the container upward <br /> 70(ANSI-CI), for Class I, Group D locations. and unobstructed to the open air..Vent pipes shall <br /> not be restrictive or smaller in size than the <br /> 3. SYSTEMS UTILIZING STATIONARY, pressure relief valve outlet connection. All pres- <br /> PIER-MOUNTED OR SKID-MOUNTED sure relief valve discharges shall have suitable <br /> ABOVEGROUND OR UNDERGROUND, rain caps that will allow free discharge of the <br /> NON-REFRIGERATED STORAGE vaporand prevent the entrance of water.Suitable <br /> This section applies to stationary,pier-mounted, provision shall be made for draining condensate <br /> skid-mounted, aboveground or underground,non- which may accumulate. <br /> refrigerated storage installations utilizing con- (b) If desired, vent pipes from two or more ' <br /> g 9 pressure relief devices located on the same unit, <br /> tainers other than those constructed in accordance or similar lines from two or more different units, <br /> 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.