My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0004714
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
2600 - Land Use Program
>
UP-98-22
>
SU0004714
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2020 1:05:24 PM
Creation date
9/6/2019 11:06:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0004714
PE
2627
FACILITY_NAME
UP-98-22
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
APN
19119006
ENTERED_DATE
11/18/2004 12:00:00 AM
SITE_LOCATION
500 E LOUISE AVE
RECEIVED_DATE
1/3/1989 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\APPL.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\CDD OK.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\EH COND.PDF \MIGRATIONS\L\LOUISE\500\UP-98-22\SU0004714\EH PERM.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
695
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\ AMERICAN NATIONAL STANDARD X61.1-1981 <br /> 5.2 Qualification Tests. The qualification tests passed around two pulleys with diameters as <br /> are intended to establish that the hose is properly shown in Table IV. A 30-pound (13.6 kg) weight <br /> designed and constructed to give satisfactory shall then be attached to the free end. <br /> service life. These tests shall be conducted by a 5.2.1.2.2 From the remainder of hose <br /> recognized independent laboratory.The qualifi- <br /> cation tests shall consist of all the tests specified length marked "I" (sizes 1 inch (25.4 mm) and <br /> herein,includingthe ammonia performance test. under only), cut a section to length indicated in <br /> Two 12-foot(3.6 m)lengths shall beselected for Table IV. Connect one end to the vertically <br /> the ammonia performance test. Each new hose traveling block as shown 1n Fig. 1, and connect <br /> design shall be subjected to a qualification test, the other end to the liquid space of a tank of <br /> and again whenever there has been a design anhydrous ammonia. Maintain the temperature <br /> change. of hose and ammonia between 70'F (21.0'C) to <br /> 90'F(32.2'C).The test on the feeder hose does not <br /> 5.2.1 Ammonia Performance Test.Two 12- apply to sizes over 1 inch (25.4 mm). To conduct <br /> foot(3.6 m)lengths of hose, to be marked"I"and the flex test on the larger sizes any convenient <br /> "II", shall be filled with liquid' anhydrous hose may be used as a feeder hose. <br /> ammonia by connecting to a tank and flushing <br /> out with ammonia to remove all the air.One end 5.2.1.2.3 The flexing test shall continue <br /> l f each length shall be sealed and the other end for 72 hours at a rate of approximately 470 cycles <br /> left connected to the liquid space a a tank a per hour with a 42-inch (1.07 m) vertical move- <br /> anhydrous ammonia. The hose shall then be ment of the traveling block.A valve between the <br /> of 60OF (1 for 14 days at Fambient(3 . temperature ammonia tank'and the hose may be closed <br /> of 60 F (15.5 C) to 100 F (37.8 C). A valve providing it is opened at least once each day to <br /> between the ammonia tank and the hose may be pressurize the hose.The hose shall be examined <br /> closed providing it is opened at least once each each day for visible defect. There shall be no <br /> anhydrous ammonia-The hose shall be examined <br /> day completely fill the hose with liquid evidence of cover blistering or leakage. <br /> each day for visible defects. There shall be no <br /> evidence of the cover blistering or perceptible 5.2.1.2.4 At the conclusion of the flexing <br /> leakage.If the hose is valved off at each end when period,cut a 24-inch(610 mm)sample from hoses <br /> liquid full, a hydrostatic relief valve should be 'I and"II"and subjecteachsample toastraight . <br /> provided between the black valves. burst test in accordance with Section 5.1.1. All <br /> samples shall have a minimum burst of 1750 psig <br /> 5.2.1.1 Conditioned Hose Burst Test.A24- (12.1MPa). <br /> inch (610 mm) sample cut from hose marked "I" 6. MARKINGS <br /> shall be subjected to a straight hydrostatic <br /> bursting test in accordance with Section 5.1.1. Hose shall be clearly marked at least once <br /> 5.2.1.2 Conditioned Hose Flexing Test every five feet with manufacturer's name or <br /> trademark, "Anhydrous Ammonia", the max- <br /> 5.2.1.2.1 The 12-foot (3.6 m) hose length imum working pressure in psig, year of manu- <br /> marked "II" shall be installed in flexing test facture, and "RMA-TFI Spec". As indicated in <br /> machine (Fig. 1). One end of the hose is to be the Scope,the maximum working pressure must <br /> connected to the traveling block and the free end not be less than 350 psig(2.4 MPa). <br /> Table IV <br /> Nominal Pulle Pulley <br /> Y Diameter Feeder <br /> I.D. Diameter Tolerance t Hose Length <br /> Inch mm Inch mm Inch mm Inch mm <br /> % (0.500) 12.7 14 355 0.250 6.4 36 915 <br /> '/, ((0.750) 19.1 14 355 0.250 6.4 36 915 <br /> 1 1.000) 25.4 14 355 0.250 6.4 36 915 <br /> 1t/, 1.250) 31.8 15 380 0.250 6.4 <br /> I% 1.500) 38.0 18 460 0.250 6.4 <br /> 2 2.000 51.0 24 610 0.250 6.4 <br /> 2'/z 2.500 64.0 30 762 0.250 6.4 <br /> 3 3-000 76.0 1 36 915 1 0.250 1 6.4 <br /> 29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.