Laserfiche WebLink
LAURENCE TEST <br /> CIVIL ENGINEER <br /> SEPTIC SYSTEM DESIGN <br /> (Per San Joaquin County Requirements) <br /> PROPOSED ADDITIONS <br /> PROPOSED LEACH LINE 100 LF <br /> TRENCH WIDTH 1 FT <br /> EQUIVALENT LENGTH 100 FT per SJCo <br /> PROPOSED PIT DIAMETER 48 IN <br /> PROPOSED PIT DEPTH 25 FT <br /> EQUIVALENT LENGTH 90 FT per SJCO <br /> TOTAL EQUIVALENT LENGTH OF LL & PITS 350 <br /> LEACH FIELD REPLACEMENT <br /> TOTAL LEACH LINE LENGTH 200 LF <br /> APPLICATION AREA 15 LF Spacing between trenches <br /> REPLACEMENT AREA 3,000 SQFT Min <br /> CONCLUSIONS <br /> THE EXISTING 1,200 GALLON TANK IS ADEQUATELY SIZED FOR THE PROPOSED LOAD <br /> INSTALLING AN ADDITIONAL 100 LF OF LEACH LINE AND A 48" PIT WILL PROVIDE AN <br /> ADEQUATE DISPOSAL AREA FOR BOTH USES. <br /> 3/17/2004 <br />