Laserfiche WebLink
AIR-COOLED PAD MOUNTED RECTIFIER AIR-COOLED PAD <br /> MOUNTED RECTIFER <br /> PAD-LOCKABLE LATCH <br /> IDENTIFICATION PLATE <br /> NEW BOLLARD 3/4"0 GRS CONDUIT W/1-,J6 AWG BARE COPPER <br /> (TYP OF 2) <br /> SEE OETAIL <br /> I"0 GRS CONDUIT W/(I)-/4 AWG THNN HEADER CABLE TO RECTIFIER POSIRVE TERMINAL. <br /> STA f— <br /> 'AfCIrFlER - <br /> ANODE JUNCTION BOX PAD-LOCKABLE <br /> SEE DETAIL LATCH <br /> CP-}9 <br /> LOCKABLE DISCONNECT SWITCH <br /> 2.0 GRS CONDUIT W/(VARIES)-ft AWG ANODE CABLES <br /> 170 GRS CONDUIT W/{i)-,J4 AWG HMWPE DRAIN CABLE d (1)--#8 AWO TEST CABLE <br /> NEW CONCRETE PAD <br /> SEE DETAIL <br /> 9'DLA. G-5 TRAFFIC BOX <br /> 2-0 GRS CONDUIT W/(3)-ft AWG THWN, XHNW AC CABLES <br /> . NEW CONCRETE PAD <br /> SEE DETAIL - - - - <br /> ICA--191 <br /> GRA—DE <br /> 2—" I \b/% a <br /> WARNING T8"(TYP) <br /> TAPWARNING <br /> ARNING TAmay\PEla\ \/fWARNING <br /> \G\%°/<" <br /> a/ <br /> /. <br /> TAPE —— <br /> RUSHING _yt.. 30"(TYP) " <br /> 5 87x8'GROUND ROD 2"0 SCH 40 PVC 270 SCH 40 PVC <br /> CONDUIT TO AC CONDUIT TO AC <br /> PULL BOX PULL 80X <br /> I (SEE NOTE 3.) o (SEF NOTE S) <br /> 110 SCH 40 PVC CONDUIT 210 SCH 40 PVC CONDUIT <br /> TO STRUCTURE TO DEEP ANODE BEDS <br /> (SEE NOTE 3.) (SEE NOTE J.) <br /> FRONT RIGHT SIDE <br /> uor£s: <br /> i <br /> 1. LEAVE SPACE AT BOTTOM OF RECTIFIER ENCLOSURE FOR AN INTERRUPTER. <br /> 2, USE PUC SCHEDULE 40 CONDUIT UNDERGROUND,AND GALVANIZED RIGID STEEL CONDUIT ABOVE GRADE. THE PORTION OF THE GALVANIZED STEEL CONDUIT WHICH IS UNDERGROUND BEFORE IT TRANSITIONS TO AVC, SHALL BE PRIMED & TAPE WRAPPED ALONG ENDRE LENGTH WITH HALF-LAP 10-01. POLYETHYLENE TAPE <br /> 3, FOR CABLE TRENCH, SEE DETAIL 2/CP-20. <br /> 4. THE DOOR OF THE RECTIFIER ENCLOSURE SHALL BE FURNISHED AN LO. PLATE AS INDICATED IN DETAIL 3/CP-19,AND SHALL ALSO INCLUDE A 10714"SIGN, BRADY 84084 OR EQUIVALENT, MARKED "DANGER HIGH VOLTAGE KEEP OUT". <br /> 5. THE DISCONNECT SWITCH MAY BE LOCATED INSIDE OR OUTSIDE OF THE RECTIFIER CABINET. <br /> (J1 PAD MOUNTED RECTIFIER INSTALLATION <br /> CPti�18 NOT 70 SCALE <br /> DEPARTMENT GF MUNICIPAL UTIL?TIES <br /> CI1Y DF STGGKTON,GALIFDRNIn <br /> �� RECOMMENDED: <br /> r.WINEERING MANAGER <br /> NO. REVISIONS BY AVT' DAIr CAMAID,PROT CII®IV HPAW SWPS&FORCEMAiNS W_ DESIGNED UNDER TI-Ii DIRcr=TIGN OF: SHEEP <br /> �y8 p4aF4551q� <br /> E MJNIC1P_UUTTLTTITS Jdh courpsion --- -i 3-20-2018 *u f <br /> DEPARTMENT c a n s u I t a n t s, i n c. ° t17 i—�� r [}I /� n m HAMMEDALI DTE <br /> Biwa / 1 �GJ t [ I), Imo.r, j{ MM ��E I r A�I S I I I R.COR,E.No.OR 1039 REG79TFATION EXPIRES t 30.9 <br /> Na r na+x 1100 Willow Pass Court, COMO LJ l U u L411 11 u L tr,1 LLLS <br /> COSIGN:TDH OATE-5-3-t 7 <br /> ANUD3mcLlon,C1 95D6 - c t <br /> I�hu„”.L2o9)'W47ra Concord, CA 94520 - DRAWN:TDIA DATES s-a-iz <br /> STOCKTUN,CALIFORNIA <br /> Tel. (925)927-6630 MUNICIPAL U7ILITES DEPARTMENT <br /> >runlclnt ulltmn ovtllTn¢In oHECHED,MA DATE:s-u-iz 13 OF 20 sHE-I s <br />