WP0039444
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8598
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0039444
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2019 4:45:02 PM
Creation date
9/6/2019 3:23:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0039444
PE
4371
STREET_NUMBER
8598
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209-
APN
07516001
ENTERED_DATE
3/14/2019 12:00:00 AM
SITE_LOCATION
8598 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1"0 HOLE (G8 CHRISTY) CONCRETE TRAFFIC <br /> (TYP OF 2) BOX W/CAST IRON LID <br /> NEW CONCRETE 80X GROUND TO SLOPE <br /> AWAY FROM WELL CONCRETE COLLAR <br /> SEE OETWL�'21 <br /> I (SEE NOTE 2.) J000 PSI SAN OUT, <br /> i \\i 6" I I TO EXrSTINGHPAVEM NALL PE If FLUSH PVC PIPE <br /> I E80 <br /> \i NEW STANDARD 12"CAST rRON VALVE BOX r <br /> RING& TRAFFIC COVER MARKED "ANODE" <br /> 2"0 PVC vENr PIPE \ LOOP ANODE CA8LF5 <br /> 2"SCH 80 PVC CONDUIT VENT <br /> CONCRETE MOUNTING PAD /�/� <br /> PREMIXED PIPE W/scREENEa END �4 RE o I. I 0 6" ��/\�/ 6"TYP <br /> SEE DETAIL O D 12" <br /> NON-SHREW4 REBAR cP�r7 CENTEF7ED p a <br /> GROUT IN COLLAR <br /> 11' CONCRETE UNPAVED AREA <br /> - COLLAR fib' <br /> 3000 PSI 6" - �OoB 13 o i/i 6"PERFORATION (TVP) <br /> PRo�rL� vr�w - <br /> a..• \ \\ `�/ 28.75" 3.75"(Tl'P) <br /> SAND 3.75"(TYP) 25" <br /> i2" <br /> 24'MIN #4 REBAR, " _ _ • ' f/16"PERrOP0cv4 <br /> FORMED IN T(1 25" (TVP) _ <br /> 5 I1° J6.75", <br /> X 25"SQUARE& 120 DEGREES <br /> 30"MIN CENTERED IN SLAB <br /> INSULATED BUSHING 6"THICK "I.•••• <br /> ANODE CABLES CONCRETE 25" <br /> MOUNTING P .. <br /> M Ap ANOQe O III <br /> (SEE NOTE 1.) 28.75" I, <br /> 4 PVC TAPE I TO NEW ANODE 'I <br /> JUNCTION BOX I <br /> COKE BREEZE 5' n I1"6 CAST IRON <br /> a 3/4'x1-1/2" UO, MARKED <br /> c� DRAIN ROCK 2"SCH 40 Pvc commr ANODE" <br /> w w r W/(2)ft AWG HALAR <br /> o HMWPE ANODE CABLES I" HOLE z <br /> 1T(P OF 2) " NOTES: <br /> 7. o 1. PERFORATE ALL LENGTHS OF PIPE THAT WILL BE <br /> 0 12"0 14 GAUGE STEEL COUPLING <br /> ANODE INSTALLATION WECC CASING (IF REQ'p . SAW CUL, SHALL TIE IN FLUSH INSTALLED IN COKE BREEZE. <br /> (TYP OF 2) To PREVENT HOLE (1F REQUIRED) TO EXISTING PAVEMENT 2. GLUE PVC JOINTS AND SECURE W/(3) J"-10 <br /> SEE DETAIL�$1 CAVE-IN) PLAN VIEW SELF TAPPING SHEET METAL SCREWS. <br /> CPvl7 ' �` PREMIXEO NON-'SHRfNK GROUT NOTES: J. PERFORATION SHALL BE COMPLETED IN THE SHOP. <br /> i 1.2, FORCTHEENSTALLATION N PAD SHALL PAVEMENTHTHELPAOrBROOM SHALL BEI FLUSH WITH THE PAVEMENT. NO FIELD PERFORATION SHALL BF ALLOWED. <br /> 2 NEW CONCRETE BOX �1 CONCRETE MOUNTING PAD 4 VENT PIPE <br /> `r CP-17 NOT TO SCALE CP-17 NOT TO SCALE CP-17 Nor TO SCALE <br /> ANODE,�z � L. <br /> 0 <br /> 2"SCH 80 J'IO AWC/HMWPE ANODE <br /> PLASTIC VENT PIPE TRASH GUARD-- CABLE(BLACK) STRANDED <br /> 5, SEE DETAIL 4 SECTION COPPER <br /> CPvl7 <br /> EPDXY ENCAPSULATION <br /> SILVER SOLDERED d <br /> 2"SCH 80 PVC f'8 AWG/HALAR-HMWPE CONNEC17ON <br /> VENT PIPE W/ ANODE CABLE j <br /> BOTTOM 29-FEET i <br /> bOLB 4R 32LB MAGNESIUM INCDT <br /> PERFORATED COKE BREEZE----_, 11'P1CAC I INGOT PER SUBMERGED <br /> TRASH RACK SECTION) <br /> SEE DETAIL © ( 60 LB. MAGNESIUM AGOT <br /> {CCPV17 <br /> SEE DETAIL 32 LB. MAGNESIUM INGOT <br /> CP-r7 <br /> 84"LONG, 2.66" ANODE CENTRALIZER '� 45" <br /> 63-POUND HIGH (TYP OF 3 @ 120 <br /> ANODE I SILICON CAST IRON DEGREES) RING TERMINAL CONNECTOR <br /> ANODE(TYPE TA-3) fiD" <br /> GALVANIZEO STEEL CORE <br /> i <br /> PVC CAP 5• SELF-TAPPING SCREW <br /> TAPE ENOS OF ANODE X10 AWG HMWPE ANODE CABLE 3 <br /> CENTRALIZERS TO <br /> --4 T2" COVER LEADING METAL <br /> EDGE IN ORDER TO <br /> PREVENT DAMAGING 316 U-BOLT&HARDWARE <br /> CABLE INSULA77ON (TVP OF 3) <br /> NOTE OURING INSTALLATION <br /> ROCKS, BOULDER, GRAVEL, DEBRIS, ETC MAY BE ENCOUNTERED �—4 <br /> DURING THE DRILLING OPERATION, THE CONTRACTOR SHALL BE NOTE: 60LB. & 32 LB. MAGNESIUM INGOT <br /> PREPARED FOR ALL ADVERSE CONDITIONS NO ADDITIONAL THE NUMBER OF THE ANODES FOR THE TRASH RACK STRUCTURE'rS DETERMINED BY INE NUMBER OF SECnoNS <br /> COMPNSARON WILL BE PROWDEO TO THE CONTRACTOR. OF THE TRASH RACK. ATTACH ONE(1)ANODE TO BOTTOM OF EACH SECTION OF THE TRASH RACK STRUCTURE. CP-17 NOT TO SCALE DEPARWENT OF MUNICIPAL UTILmEs <br /> �� ' <br /> NEW DEEP ANODE BED (-5-)ANODE WSTALLA TION (6-� WET WELL TRASH GUARD - ANODE INSTALLATION GITY OF STOCKTON,CALIFORNIA <br /> CP--17 NOT TO SCALE CP-f7 NOT TO SCALE CP-17 NOT TO SCALE �l"✓:I:� P' RECOMMENDED: <br /> 'cNG1NF-RING M.ANACE i <br /> Nq REl+Is1DN5 ©Y APP DATE a � Cc51GNE0 UNDER l'HE DIRF_GT10N OF: H..F i <br /> J JJLL GAMODIC PROTECTMol REPAIRS SWPS el FORCEIVIAINS gaarEssr <br /> ■rrl� nn�xrcrP_•u.urrT.rTrLs �� JU11 C���Os��n � - 3--20-2018 „� '4� � <br /> DLPARTI[EN'T W c o n s u 1 t a n t s, 1 n c. rrnnttNpJI sF. r� rIn Era MOHAMMEDALI oaf <br /> �r (}T l Oo L�fI C� C�f 1 00TECP����� 1111 �I ! f`I P.COR.E.No.CR 1 W5 PEGIVFATION EXPIRES 6?o-*g 6 no.Cq 1 35 <br /> 2sooN,tyno," 1100 Willow Pass Court, -- u L *�'r ao'mw* <br /> DESIGN:TDH DATE:5-3-77 <br /> P1,cuc,�(.09)937,8700 Concord, CA 94520 - - - --- - DRAWN:TDH DATE:5-3-17 �f�rf OF CPL1i�p <br /> IMUD�!nu�.a:uea,snosrAerelua Tel. (925)927-6630 STOCKTON,CALIFORNIA MUNICIPAL OTILITES DEPARTMENT f CHECKED MA DATE:5.3-17 17 oP 2Q swEFTs <br />