Laserfiche WebLink
Table 2. Percolation Test Summary <br /> Test No., Percolation Percolation Test Duration Comments <br /> Date Tested Test Rate (see notes) <br /> Depth (ft.) (minutes/inch) <br /> P1, Satisfactory <br /> 12/10/10 3.20 4.4 4 hr. <br /> Shallow Test perc. rate <br /> Note: A satisfactory percolation rate for a "shallow"test is less than or equal to 60 minutes per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the tested area of the Site have demonstrated a satisfactory percolation <br /> rate for the use of a standard septic system in accordance with the requirements of the <br /> San Joaquin County Environmental Health Department. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines and sumps up to 10' deep should follow <br /> the San Joaquin County On-Site Wastewater Disposal Standards (2003) where <br /> applicable. <br /> LOGE 1103 Page 7 <br />