My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0007443 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PELTIER
>
10020
>
2600 - Land Use Program
>
PA-0800323
>
SU0007443 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:04 AM
Creation date
9/8/2019 12:39:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0007443
PE
2622
FACILITY_NAME
PA-0800323
STREET_NUMBER
10020
Direction
W
STREET_NAME
PELTIER
STREET_TYPE
RD
City
THORNTON
APN
01106002
ENTERED_DATE
10/27/2008 12:00:00 AM
SITE_LOCATION
10020 W PELTIER RD
RECEIVED_DATE
10/27/2008 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PELTIER\10020\PA-0800323\SU0007443\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 23, 2009 Page 8 of 10 <br /> Our Project Number: LGS0090518 <br /> • Utilize standard filter bed system design with the following exceptions. <br /> • Minimum Septic Tank Sizes <br /> 2 bedroom — 1200 <br /> 3 bedroom — 1600 <br /> 4 bedroom — 2000 <br /> 5 bedroom — 2400 <br /> 6 bedroom — 3200 <br /> 7 bedrooms and above will require consultation. <br /> • Apply 4 inches of compost or peat in the bottom of the filter bed. Utilize gravel <br /> drain systems to improve denitrification. <br /> 6.0 CONCLUSIONS <br /> In summary, percolation rates that meet the minimum EHD standards were achieved in the <br /> proposed septic disposal areas of each of the proposed parcels. The-parcels-appear—sWtablefiar P � <br /> the use of a standard-septic--system. However, since groundwater is high-within-the-area of the <br /> site and varies we recommend the use of mounded septic systems. We t anticipaw-that ANEV• <br /> the ground water quality will be negatively impacted primarily due to t sten e.of_peat_and—, <br /> ne-grained W's. Furthermore, these conditions are favorable for the removal of nitrate from [b?� <br /> sep i sem effluent. <br /> Ground water w,ok encountered on parcel 5 at four feet below ground surface. The on-site <br /> water well was tested for nitrate and DBCP. DBCP was not detected, and therefore was not <br /> above the MCL water limit of 0.2 pg/L.DBCP was detectable. The nitrate concentration in <br /> ground water was found to 1.8 mg/L, which is well below the maximum contaminant drinking <br /> water limit of 45 mg/L-NO3. <br /> 7.0 LIMITATIONS <br /> The conclusions of this report are based on the information provided regarding the existing and <br /> proposed development, the use of the subject property, and the site conditions as they existed <br /> at the time we excavated our test holes and performed the percolation tests. It was assumed <br /> that the test holes and percolation test results are representative of the subsurface conditions in <br /> the general area. <br /> If there is a substantial lapse of time between the submission of our report and the start of <br /> work at the site, or if conditions have changed due to natural causes or construction operations <br /> at or adjacent to the site, we urge that our report be reviewed to determine the applicability of <br /> the conclusions and recommendations considering the changed conditions and time lapse. This <br /> report is applicable only for the project and site studied. This report should not be used <br /> after 3 years without the review and update from our office. <br /> Our professional services were performed, our findings obtained, and our conclusions proposed <br /> in accordance with generally accepted engineering principles and practices. This warranty is in <br /> 902 Industrial Way•Lodi,CA 95240•209.367.3701 •Fax 209.369.4228 02009 Nett a Anderson&Associates,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.